(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
An easy-to-remove relay type is being added one by one! Encoder cable with a specified length (0.2 to 50 m)! Opposite load side type or angle that pulls out the cable on the opposite side of the motor rotation axis, which is not available in the optional cable Types are also available. Fixed or movable cables can be selected.
Cable for Connections (Dual-end processed type). In case you need a cable over 10m long, use "Long Distance Type" cables.
Load Side Leading...Motor Shaft Side Cable Leading, Anti-Load Side Leading...Anti-Motor Shaft Side Cable Leading
* Cable length specifiable by 0.1 m increments
Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
MR-J4-□ MR-J3-□ MR-JN□ Standard Type (Up to 10 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (1) For Direct Connection | Dual End (Load Side Leading) | SVEM-J3HF1 | A (For Fixed) 0.2 ~ 10 m B (For Movable) 0.2 ~ 10 m |
Dual End (Anti-Load Side Leading) | SVEM-J3HF1R | ||||
HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (2) For Direct Connection | Double-ended | SVEM-J3HF2 | ||
MR-J4-□ MR-J3-□ MR-JN□ Long Distance Type (Up to 50 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (3) Amplifier Side Relay *1 (* Use with 2 as a set) | Dual End: 1 ~ 20 m | SVEM-J3HF1L-C20 | C (for fixed) 1 ~ 20m |
Dual End: 20 ~ 30m | SVEM-J3HF1L-C30 | C (for fixed) 20 ~ 30m | |||
Dual End: 1 ~ 20 m | SVEM-J3HF1L-D20 | D(for movable) 1 ~ 20 m | |||
Dual End: 20 ~ 50 m | SVEM-J3HF1L-D50 | D(for movable) 20 ~ 50m | |||
(4) Motor Side Relay *2 (* Use with 1 as a set) | Two Ends (Load Side) | SVEM-J3HF1M | A (for fixed) 0.2 ~ 0.3 m B (for movable) 0.2 ~ 10 m | ||
Both Ends (Anti-Load Side) | SVEM-J3HF1RM | ||||
HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (2) For Direct Connection | Double-ended | SVEM-J3HF2L | C (for fixed) 10 ~ 30 m D (for movable) 10 ~ 50m |
Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
MR-J4-□ MR-J3-□ MR-JN□ Standard Type (Up to 10 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (5) Amplifier Side, One-End | Cut off | SVEM-J3HF1-HA | ![]() |
Motor Side Connector Set (Load Side) | SVEM-J3HF1-HASET | ||||
(6) Motor Side, One-End (Load Side Leading) | Cut off | SVEM-J3HF1-HM | |||
Amplifier Side Connector Set | SVEM-J3HF1-HMSET | ||||
(6) Motor Side, One-End (Anti-Load Side Leading) | Cut off | SVEM-J3HF1R-HM | |||
Amplifier Side Connector Set | SVEM-J3HF1R-HMSET | ||||
HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (8) Amplifier Side, One-End | Cut off | SVEM-J3HF2-HA | ||
Motor Side Connector Set | SVEM-J3HF2-HASET | ||||
(9) Motor Side, One-End | Cut off | SVEM-J3HF2-HM | |||
Amplifier Side Connector Set | SVEM-J3HF2-HMSET | ||||
MR-J4-□ MR-J3-□ MR-JN□ Long Distance Type (Up to 50 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (7) Amplifier Side Relay *1 (* Use with 2 as a set) | One End + Connector for Relay 10 ~ 20 m | SVEM-J3HF1L-HASET-C20 | C (for fixed) 10 ~ 20m |
One End + Connector for Relay: 20 ~ 30 m | SVEM-J3HF1L-HASET-C30 | C (for fixed) 20 ~ 30m | |||
One End + Connector for Relay 10 ~ 20 m | SVEM-J3HF1L-HASET-D20 | D(for movable) 10 ~ 20 m | |||
One End + Connector for Relay: 20 - 50 m | SVEM-J3HF1L-HASET-D50 | D(for movable) 20 ~ 50m | |||
HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (8) Amplifier Side, One-End | Cut off | SVEM-J3HF2L-HA | C (For Fixed) 10 ~ 30m D (For Movable) 10 ~ 50m | |
Motor Side Connector Set | SVEM-J3HF2L-HASET | ||||
(9) Motor Side, One-End | Cut off | SVEM-J3HF2L-HM | |||
Amplifier Side Connector Set | SVEM-J3HF2L-HMSET |
Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
MR-J3-□ Standard Type (Up to 10 m) | HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ | (10) For Direct Coupling | Double-ended | SVEM-J3HF2AL | ![]() |
(11) Amplifier Side, One-End | Motor Side Cut Off | SVEM-J3HF2AL-HA | |||
Motor Side Connector Set | SVEM-J3HF2AL-HASET | ||||
(12) Motor Side, One-End | Amplifier Side Cut Off | SVEM-J3HF2AL-HM | |||
Amplifier Side Connector Set | SVEM-J3HF2AL-HMSET | ||||
(10) For Direct Connection | Double-ended | SVEM-J3HF2LAL | ![]() | ||
(11) Amplifier Side, One-End | Motor Side Cut Off | SVEM-J3HF2LAL-HA | |||
Motor Side Connector Set | SVEM-J3HF2LAL-HASET | ||||
(12) Motor Side, One-End | Amplifier Side Cut Off | SVEM-J3HF2LAL-HM | |||
Amplifier Side Connector Set | SVEM-J3HF2LAL-HMSET |
Specified Length (m) | ~ 0.9 | 1 ~ 4 | 4.1 ~ 50 |
Tolerance | +20 mm | +50 mm | + 3% of Specified Length |
Part Number |
---|
SVEM-J3HF1-A-[0.2-10/0.1] |
SVEM-J3HF1-B-[0.2-10/0.1] |
SVEM-J3HF1-HA-A-[0.2-10/0.1] |
SVEM-J3HF1-HA-B-[0.2-10/0.1] |
SVEM-J3HF1-HASET-A-[0.2-30/0.1] |
SVEM-J3HF1-HASET-B-[0.2-30/0.1] |
SVEM-J3HF1-HM-A-[0.2-10/0.1] |
SVEM-J3HF1-HM-B-[0.2-10/0.1] |
SVEM-J3HF1-HMSET-A-[0.2-30/0.1] |
SVEM-J3HF1-HMSET-B-[0.2-30/0.1] |
SVEM-J3HF1L-C20-C-[1-20/0.1] |
SVEM-J3HF1L-C30-C-[20-30/0.1] |
SVEM-J3HF1L-D20-D-[1-20/0.1] |
SVEM-J3HF1L-D50-D-[20-50/0.1] |
SVEM-J3HF1L-HASET-C20-C-[0.2-30/0.1] |
SVEM-J3HF1L-HASET-C30-C-[0.2-30/0.1] |
SVEM-J3HF1L-HASET-D20-D-[0.2-30/0.1] |
SVEM-J3HF1L-HASET-D50-D-[10-50/0.1] |
SVEM-J3HF1M-A-[0.2-5/0.1] |
SVEM-J3HF1M-B-[0.2-5/0.1] |
SVEM-J3HF1R-A-[0.2-10/0.1] |
SVEM-J3HF1R-B-[0.2-10/0.1] |
SVEM-J3HF1R-HM-A-[0.2-10/0.1] |
SVEM-J3HF1R-HM-B-[0.2-10/0.1] |
SVEM-J3HF1R-HMSET-A-[0.2-30/0.1] |
SVEM-J3HF1R-HMSET-B-[0.2-30/0.1] |
SVEM-J3HF1RM-A-[0.2-5/0.1] |
SVEM-J3HF1RM-B-[0.2-5/0.1] |
SVEM-J3HF2-A-[0.2-10/0.1] |
SVEM-J3HF2-B-[0.2-10/0.1] |
SVEM-J3HF2-HA-A-[0.2-10/0.1] |
SVEM-J3HF2-HA-B-[0.2-10/0.1] |
SVEM-J3HF2-HASET-A-[0.2-30/0.1] |
SVEM-J3HF2-HASET-B-[0.2-30/0.1] |
SVEM-J3HF2-HM-A-[0.2-10/0.1] |
SVEM-J3HF2-HM-B-[0.2-10/0.1] |
SVEM-J3HF2-HMSET-A-[0.2-30/0.1] |
SVEM-J3HF2-HMSET-B-[0.2-30/0.1] |
SVEM-J3HF2AL-A-[0.2-10/0.1] |
SVEM-J3HF2AL-B-[0.2-20/0.1] |
SVEM-J3HF2AL-HA-A-[0.2-10/0.1] |
SVEM-J3HF2AL-HA-B-[0.2-10/0.1] |
SVEM-J3HF2AL-HASET-A-[0.2-10/0.1] |
SVEM-J3HF2AL-HASET-B-[0.2-10/0.1] |
SVEM-J3HF2AL-HM-A-[0.2-10/0.1] |
SVEM-J3HF2AL-HM-B-[0.2-10/0.1] |
SVEM-J3HF2AL-HMSET-A-[0.2-10/0.1] |
SVEM-J3HF2AL-HMSET-B-[0.2-10/0.1] |
SVEM-J3HF2L-C-[10-30/0.1] |
SVEM-J3HF2L-D-[10-50/0.1] |
SVEM-J3HF2L-HA-C-[10-50/0.1] |
SVEM-J3HF2L-HA-D-[10-50/0.1] |
SVEM-J3HF2L-HASET-C-[10-30/0.1] |
SVEM-J3HF2L-HASET-D-[10-30/0.1] |
SVEM-J3HF2L-HM-C-[10-50/0.1] |
SVEM-J3HF2L-HM-D-[10-50/0.1] |
SVEM-J3HF2L-HMSET-C-[10-30/0.1] |
SVEM-J3HF2L-HMSET-D-[10-50/0.1] |
SVEM-J3HF2LAL-C-[10-30/0.1] |
SVEM-J3HF2LAL-D-[10-50/0.1] |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Length (m) | Connector shape | Outer diameter image | Cable type | Supported motors | Cable length designated range (m) | Specified Length (m) | Specified Length (M) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | - | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 10 ~ 20 | 1 ~ 20 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 20 ~ 30 | 20 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 10 ~ 20 | 1 ~ 20 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 20 ~ 50 | 20 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 10 ~ 20 | - | 0.2 ~ 30 | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 20 ~ 30 | - | 0.2 ~ 30 | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 10 ~ 20 | - | 0.2 ~ 30 | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 20 ~ 50 | - | 10 ~ 50 | ||
- | 1 Piece(s) | 5 Day(s) or more | 0.3 | Straight | Two Ends (Load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | - | 0.2 ~ 5 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | 0.3 | Straight | Two Ends (Load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | - | 0.2 ~ 5 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Both Ends (Anti-load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Both Ends (Anti-load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Anti-Load-side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Anti-Load-side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | 0.3 | Straight | Both Ends (Anti-load Side) | Mounted | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | - | 0.2 ~ 5 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | 0.3 | Straight | Both Ends (Anti-load Side) | Mobile | ( HG-KR□ / HG-MR□ / HF-KP□ / HF-MP□ / HF-KN□ ) | - | 0.2 ~ 5 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Both Ends (Anti-load Side) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Two Ends (Load Side) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Two Ends (Load Side) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 20 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Motor Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Motor Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Motor Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Amplifier Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Amplifier Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Amplifier Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Amplifier Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 0.2 ~ 10 | 0.2 ~ 10 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Two Ends (Load Side) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Straight | Amplifier Side Cut Off (Connector Set) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 50 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Two Ends (Load Side) | Mounted | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 30 | 10 ~ 30 | - | ||
- | 1 Piece(s) | 5 Day(s) or more | - | Angle | Two Ends (Load Side) | Mobile | ( HF-SP□ / HC-LP□ / HC-RP□ / HC-UP□ / HA-LP□ / HF-JP□ ) | 10 ~ 50 | 10 ~ 50 | - |
Part Number |
---|
Loading...Tải…
Supported equipment | Servo | Application 1 | For Encoder | Shield | Yes |
---|---|---|---|---|---|
Supported amplifiers | MR-J4-□ MR-J3-□ MR-JN-□ |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy