(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Safety limit switch standards. Enriched products provided globally
Note: Limit Switch, The dimensional tolerance of all parts not specified in the above dimensional diagrams for each model is ±0.4 mm.
*For the M12 connector, see "1-conduit type, M12 connector type common."
*For information on model numbers other than those listed above, please refer to the digital catalog.
Protective structure*1 of Limit Switch | IP67 (EN60947-5-1) | |
---|---|---|
Durability*2 | Mechanical | Over 1 million times |
Electrical | 500,000 times or more (AC250V 3A, resistive load)*3 300,000 times or more (AC250V 10A, resistive load) | |
Allowable Operating Speed | 1 to 500 mm/s (D4N-1A20R) | |
Allowable operating frequency | Maximum 30 times/min | |
Contact Resistance | 25mΩ or less | |
Minimum applicable load*4 | DC5V 1mA resistive load (N level reference value) | |
Rated insulation voltage (Ui) | 300V | |
Rated Frequency | 50/60Hz | |
Electric shock protection class | Class II (double insulated) | |
Pollution level (usage environment) | Pollution degree 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) | Between same-polarity terminals | 2.5kV |
Between different terminals | 4kV | |
Between each terminal and non-current-carrying metal parts | 6kV | |
Insulation resistance | 100MΩ or more | |
Contact Gap | Minimum 2 x 2 mm | |
vibration | malfunction | 10 to 55Hz, single amplitude 0.75mm |
impact | Durability | 1,000m/s2 |
malfunction | 300m/s2 | |
Conditional Short Circuit Current | 100A (EN60947-5-1) | |
Rated open thermal current (Ith) | 10A (EN60947-5-1) | |
Ambient temperature | -30 to +70℃ (but do not freeze) | |
Ambient humidity | 95% RH or less | |
mass | Approximately 92g (for D4N-1A20R) |
Note 1. The above values ​​are initial values of Limit Switch.
2. Once a load has been switched, a load with a smaller capacity cannot be connected to the contact. This
may cause the contact surface to become rough and the contact reliability to be impaired.
*1. This protective structure is based on a test method based on the standard (EN60947-5-1), and the sealing performance under the actual usage environment and conditions should be confirmed in advance.
The switch box body is protected from the intrusion of dust, oil, water, etc., but the operation key insertion port in the head part should not be exposed to cutting chips, oil, water, chemicals,etc., when using the switch. This
may cause early wear, damage, and failure of Limit Switch.
*2. The durability conditions are at an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. Do not apply AC250V 3A to two or more circuits.
*4. This value may change depending on the switching frequency, environmental conditions, reliability level, etc. Please check with the actual load in advance.
Part Number |
---|
D4N-4D26 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Detector Shape | Main Body Size | Environment | Plunger Shape Type | Roller Lever Shape Type | Lever Shape Type | Rod Shape Type | Acquired Standards | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Max. Angle T.T (deg) | Contact Type | Contact Point Type | Mechanical Life (10,000 times) | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Detector element details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Torque necessary for operation, OF (N·m) | Conduit size | Specification of Terminal | Details Type | O.D. | Mounting system | Direction of Operation | Roller Type | Contact format | Release key type | Lock / release system | Built-in Switch Specification | AC Rated Voltage | DC Rated Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,097,886 VND | 1 Piece(s) | 14 Day(s) | Roller lever type | Small | Standard | - | - | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | 1500 | - | - | - | - | - | - | Roller lever type (metal lever, bearing roller) | - | - | - | - | M20 | - | 1-conduit type, general type | - | - | - | - | - | - | - | 3NC contact (slow action) | 120 / 240 | 125 / 250 |
Loading...Tải…
Operating Temperature Range(°C) | -30::70 | Protection Structure | IP67 | Mechanical Operation Frequency(times/min or Less) | 30 |
---|
Please check the type/dimensions/specifications of the part D4N-4D26 in the Small Safety Limit Switch [D4N] series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần D4N-4D26 trong chuỗi Small Safety Limit Switch [D4N].
Part Number |
---|
D4N-1126 |
D4N-112G |
D4N-112H |
D4N-4D32 |
D4N-4F20 |
D4N-4F26 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Detector Shape | Main Body Size | Environment | Plunger Shape Type | Roller Lever Shape Type | Lever Shape Type | Rod Shape Type | Acquired Standards | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Max. Angle T.T (deg) | Contact Type | Contact Point Type | Mechanical Life (10,000 times) | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Detector element details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Torque necessary for operation, OF (N·m) | Conduit size | Specification of Terminal | Details Type | O.D. | Mounting system | Direction of Operation | Roller Type | Contact format | Release key type | Lock / release system | Built-in Switch Specification | AC Rated Voltage | DC Rated Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
895,093 VND | 1 Piece(s) | 14 Day(s) | Roller lever type | Small | Standard | - | - | - | - | EN / UL / C-UL / CE / GB(CCC) / TUV | - | - | - | - | - | - | - | 1500 | - | - | - | - | - | - | Roller lever type (metal lever, bearing roller) | - | - | - | - | PG13.5 | - | 1-conduit type, general type | - | - | - | - | - | - | - | 1NC/1NO contact (snap action) | 120 / 240 | 125 / 250 | ||
448,000 VND | 1 Piece(s) | Same day | Roller Lever Type (rotation) | Small | Standard | - | Variable Roller Levers | - | - | EN / UL / GB(CCC) / TUV | 4.5 | - | 18-27 | - | 80 | 2-circuit Double-break | - | 1500 | DC250V / DC125V | 2.5 | 31 | 45 | 82.5 | 20-66 | Variable roller lever | - | - | - | - | PG13.5 | - | 1 Conduit Shape 2 Contact Series | φ17.5×6.8 | Front mounting | Snap action (direct circuit opening operation included) | Metal lever / resin roller, foam lock type | 1NC/1NO | - | - | - | - | - | ||
680,968 VND | 1 Piece(s) | 6 Day(s) or more | Roller Lever Type (rotation) | Small | Standard | - | Variable Roller Levers | - | - | EN / UL / GB(CCC) / TUV | 4.5 | - | 18-27 | - | 80 | 2-circuit Double-break | - | 1500 | DC250V / DC125V | 2.5 | 31 | 48.2 | 82.5 | 32-66 | Variable roller lever | - | - | - | - | PG13.5 | - | 1 Conduit Shape 2 Contact Series | φ50×8 | Front mounting | Snap action (direct circuit opening operation included) | Metal lever / rubber roller, foam lock type | 1NC/1NO | - | - | - | - | - | ||
550,788 VND | 1 Piece(s) | 6 Day(s) or more | Plunger Type | Small | Standard | [Roller Plungers] Top, Roller Plunger | - | - | - | EN / UL / GB(CCC) / TUV | 6.5 | 2 | - | 6 | - | 2-circuit Double-break | - | 1500 | DC250V / DC125V | 2.5 | 31 | 31.5 | 83.6 | - | Roller plunger type (resin roller) | - | 4 | 28.2±0.8 | - | M20 | - | 1 Conduit Shape 2 Contact Series | φ9.5×5 | Front mounting | Slow action (direct circuit opening operation included) | Plastic Rollers | 3NC | - | - | - | - | - | ||
589,511 VND | 1 Piece(s) | 14 Day(s) | Roller lever type | Small | Standard | - | - | - | - | EN / UL / C-UL / CE / GB(CCC) / TUV | - | - | - | - | - | - | - | 1500 | - | - | - | - | - | - | Roller lever type (resin lever, resin roller) | - | - | - | - | M20 | - | 1-conduit type, general type | - | - | - | - | - | - | - | 2NC/1NO contact (MBB) (slow action) | 120 / 240 | 125 / 250 | ||
1,140,915 VND | 1 Piece(s) | 13 Day(s) | Roller lever type | Small | Standard | - | - | - | - | EN / UL / C-UL / CE / GB(CCC) / TUV | - | - | - | - | - | - | - | 1500 | - | - | - | - | - | - | Roller lever type (metal lever, bearing roller) | - | - | - | - | M20 | - | 1-conduit type, general type | - | - | - | - | - | - | - | 2NC/1NO contact (MBB) (slow action) | 120 / 240 | 125 / 250 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy