(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
PRCMT12-2DC |
PRCMT12-2DO |
PRCMT12-4DC |
PRCMT12-4DO |
PRCMT18-5DC |
PRCMT18-5DO |
PRCMT18-8DC |
PRCMT18-8DO |
PRCMT30-10DC |
PRCMT30-10DO |
PRCMT30-15DC |
PRCMT30-15DO |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Shield | Detection Head Size, Dimension M | Detection Head Size, Dimension D (Ø) | Standard Detector | Setting distance (mm) | Response frequency (Hz) | Model configuration control output (or output) | Influence of temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|
920,464 VND | 1 Piece(s) | 18 Day(s) | Shield | M12 | 21 | 12 x 12 x 1 mm (iron) | 0~1.4 | 1500 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
918,793 VND | 1 Piece(s) | 5 Day(s) | Shield | M12 | 21 | 12 x 12 x 1 mm (iron) | 0~1.4 | 1500 | Normally Open | ± 10% or less of sensing range at 20°C in the operating ambient temperature range, PR05 Series: ± 20% or less | ||
920,464 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M12 | 21 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
733,626 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M12 | 21 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
908,314 VND | 1 Piece(s) | 18 Day(s) | Shield | M18 | 29 | 18 x 18 x 1 mm (iron) | 0~3.5 | 350 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
908,314 VND | 1 Piece(s) | 18 Day(s) | Shield | M18 | 29 | 18 x 18 x 1 mm (iron) | 0~3.5 | 350 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
908,314 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M18 | 29 | 25X25X1 mm (iron) | 0~5.6 | 400 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
908,314 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M18 | 29 | 25X25X1 mm (iron) | 0~5.6 | 400 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
981,209 VND | 1 Piece(s) | Available | 18 Day(s) | Shield | M30 | 42 | 30X30X1 mm (iron) | 0~7 | 200 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | |
981,209 VND | 1 Piece(s) | 18 Day(s) | Shield | M30 | 42 | 30X30X1 mm (iron) | 0~7 | 200 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
981,209 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 45X45X1 mm (iron) | 0~10.5 | 200 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | ||
981,209 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 45X45X1 mm (iron) | 0~10.5 | 200 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range |
Loading...Tải…
Sensor Shape | Cylindrical type | Detection Object | Magnetic Metal | Operating Environment | Standard |
---|---|---|---|---|---|
Detection Type | Front detection | Sensor Case Material | Brass (Nickel-plated) | Sensor Detection Surface Material | ABS resin |
Amplifier | Built-in type | Acquired Standards | CE | Protection Structure (IEC) | IP67 |
Hysteresis distance | 10% or less of detection distance | Power Voltage (Operational Voltage Range) | 12-24VDC(10-30VDC) | Leakage current(mA) | 0.6 or less |
Residual Voltage(V) | 3.5 or less | Control Output(mA) | 2~100 | Insulation resistance(㏁) | 50 or more (500 VDC megger) |
Withstand Voltage | At 1,500 VAC 50/60 Hz for 1 min | Vibration resistant | 10-55 Hz (1 minute cycle) multiple amplitude 1 mm each X, Y, Z direction 2 hours | Impact resistance | 500 m/s² (approximately 50 G) 3 times for each X, Y, Z direction |
Indicator Lamp | Operation indicator (red LED) | Operating Ambient Temperature(℃) | -25 – 70, for storage: -30 – 80 | Operating Ambient Humidity(%RH) | 35-95, for storage: 35-95 |
Protection circuit | Surge protection circuit, overcurrent protection circuit | Material | Washer: Nickel plated iron, |
How can we improve?