(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
PRT08-1.5DC |
PRT08-1.5DO |
PRT08-2DC |
PRT08-2DO |
PRT12-2DC |
PRT12-2DO |
PRT12-4DC |
PRT12-4DO |
PRT18-5DC |
PRT18-5DO |
PRT18-8DC |
PRT18-8DO |
PRT30-10DC |
PRT30-10DO |
PRT30-15DC |
PRT30-15DO |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Shield | Detection Head Size, Dimension M | Detection Head Size, Dimension D (Ø) | Detection Head Size, Dimension L2 (mm) | Standard Detector | Setting distance (mm) | Response frequency (Hz) | Response frequency (kHz) | Model configuration control output (or output) | Influence of temperature | Protection circuit | Wiring specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
847,571 VND | 1 Piece(s) | 5 Day(s) | Shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.05 | - | 1.5 | Normally Closed | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ3.5, 3 cores, 2 m (AWG 24, wire diameter: 0.08 mm, number of wires: 40, outer diameter of insulator: φ1) | ||
847,571 VND | 1 Piece(s) | 5 Day(s) | Shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0~1.05 | - | 1.5 | Normally Open | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ3.5, 3 cores, 2 m (AWG 24, wire diameter: 0.08 mm, number of wires: 40, outer diameter of insulator: φ1) | ||
847,571 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M8 | 15 | 30 | 8X8X1 mm (iron) | 0`1.4 | - | 1 | Normally Closed | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ3.5, 3 cores, 2 m (AWG 24, wire diameter: 0.08 mm, number of wires: 40, outer diameter of insulator: φ1) | ||
686,292 VND | 1 Piece(s) | 4 Day(s) | Non-shield | M8 | 15 | 30 | 8 x 8 x 1 mm (iron) | 0~1.4 | - | 1 | Normally Open | ± 20 % or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit | φ3.5, 3 cores, 2 m (AWG 24, wire diameter: 0.08 mm, number of wires: 40, outer diameter of insulator: φ1) | ||
841,497 VND | 1 Piece(s) | 18 Day(s) | Shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0`1.4 | - | 1.5 | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4 , 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
618,229 VND | 1 Piece(s) | 5 Day(s) | Shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0`1.4 | - | 1.5 | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4 , 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
841,497 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4 , 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
630,183 VND | 1 Piece(s) | 4 Day(s) | Non-shield | M12 | 21 | 42.5 | 12 x 12 x 1 mm (iron) | 0~2.8 | 500 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ4 , 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
713,936 VND | 1 Piece(s) | Available | 18 Day(s) | Shield | M18 | 29 | 47 | 18 x 18 x 1 mm (iron) | 0~3.5 | 500 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | |
713,936 VND | 1 Piece(s) | 5 Day(s) | Shield | M18 | 29 | 47 | 18 x 18 x 1 mm (iron) | 0~3.5 | 500 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
713,936 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M18 | 29 | 47 | 25X25X1 mm (iron) | 0`5.6 | 350 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
713,936 VND | 1 Piece(s) | 5 Day(s) | Non-shield | M18 | 29 | 47 | 25X25X1 mm (iron) | 0`5.6 | 350 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
795,939 VND | 1 Piece(s) | 18 Day(s) | Shield | M30 | 42 | 58 | 30X30X1 mm (iron) | 0~7 | 400 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
795,939 VND | 1 Piece(s) | 18 Day(s) | Shield | M30 | 42 | 58 | 30X30X1 mm (iron) | 0~7 | 400 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
795,939 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 58 | 45X45X1 mm (iron) | 0~10.5 | 200 | - | Normally Closed | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) | ||
795,939 VND | 1 Piece(s) | 18 Day(s) | Non-shield | M30 | 42 | 58 | 45X45X1 mm (iron) | 0~10.5 | 200 | - | Normally Open | ± 10% or less of sensing distance at 20°C in the operating ambient temperature range | Surge protection circuit, overcurrent protection circuit | φ5, 2 cores, 2 m (AWG 22, wire diameter: 0.08 mm, number of wires: 60, outer diameter of insulator: φ1.25) |
Loading...Tải…
Sensor Shape | Cylindrical type | Detection Object | Magnetic Metal | Operating Environment | Standard |
---|---|---|---|---|---|
Detection Type | Front detection | Sensor Case Material | Brass (Nickel-plated) | Sensor Detection Surface Material | ABS resin |
Acquired Standards | CE | Protection Structure (IEC) | IP67 | Hysteresis distance | 10% or less of detection distance |
Power Voltage (Operational Voltage Range) | 12-24VDC(10-30VDC) | Leakage current(mA) | 0.6 or less | Residual Voltage(V) | 3.5 or less (5 for nonpolar type) |
Control Output(mA) | 100 or less | Insulation resistance(㏁) | 50 or more (500 VDC megger) | Withstand Voltage | At 1,500 VAC 50/60 Hz for 1 min |
Vibration resistant | 10-55 Hz (1 minute cycle) multiple amplitude 1 mm each X, Y, Z direction 2 hours | Impact resistance | 500 m/s² (approximately 50 G) 3 times for each X, Y, Z direction | Indicator Lamp | Operation indicator (red LED) |
Operating Ambient Temperature(℃) | -25 – 70, for storage: -30 – 80 | Operating Ambient Humidity(%RH) | 35-95, for storage: 35-95 | Material | Washer: Nickel plated iron, standard type cable (Black): Polyvinyl chloride (PVC), Oil resistant reinforced cable (Gray): Polyvinyl chloride (Oil resistant reinforced PVC) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy