(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Part Number |
---|
VTM5X3-A2-DN-2-E |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Maximum Intake Flow Rate | Number of Vacuum Stacks | Lead wire takeout | Sealing material | Air supply valve | Intake Flow Rate at Vacuum Level of 0 kPa (Nl/min) (Nl/m) | Noise level (s/l) | Vacuum Intake Port | 10kPa (Nl/m) | 20kPa (Nl/m) | 30kPa (Nl/m) | 40kPa (Nl/m) | 50kPa (Nl/m) | 60kPa (Nl/m) | 70kPa (Nl/m) | 80kPa (Nl/m) | 20kPa (s/l) | 30kPa (s/l) | 40kPa (s/l) | 50kPa (s/l) | 60kPa (s/l) | 70kPa (s/l) | 80kPa (s/l) | 90kPa | Maximum Vacuum Level | Mounting hole size | Minimum Hose Internal Diameter (within 2 m) (Air Supply) | Minimum Hose Internal Diameter (within 2 m) (Vacuum) | Minimum Hose Internal Diameter (within 2 m) (Exhaustion) | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
13,099,378 VND | 1 Piece(s) | 10 Day(s) | 27X3Nl/min | 3-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | 27 | 60~65 dBA | 2 | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | 2 - Ø3.4 | >2 | >2.5 | 3/8"X1 | 80 |
Loading...Tải…
Operating Environment | Standard | Operating Temperature(℃) | -20~80 | Supply air pressure | 4~6 bar, max 7 bar |
---|
Please check the type/dimensions/specifications of the part VTM5X3-A2-DN-2-E in the M-Mini Multiple Pump series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần VTM5X3-A2-DN-2-E trong chuỗi M-Mini Multiple Pump.
Part Number |
---|
VTM10X10-A1-DL-4 |
VTM10X10-A1-DL-4-E |
VTM10X10-A1-DL-4-V |
VTM5X3-A2-DN-2-V |
VTM5X3-A2-DN-4 |
VTM5X3-A2-DN-4-E |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Maximum Intake Flow Rate | Number of Vacuum Stacks | Lead wire takeout | Sealing material | Air supply valve | Intake Flow Rate at Vacuum Level of 0 kPa (Nl/min) (Nl/m) | Noise level (s/l) | Vacuum Intake Port | 10kPa (Nl/m) | 20kPa (Nl/m) | 30kPa (Nl/m) | 40kPa (Nl/m) | 50kPa (Nl/m) | 60kPa (Nl/m) | 70kPa (Nl/m) | 80kPa (Nl/m) | 20kPa (s/l) | 30kPa (s/l) | 40kPa (s/l) | 50kPa (s/l) | 60kPa (s/l) | 70kPa (s/l) | 80kPa (s/l) | 90kPa | Maximum Vacuum Level | Mounting hole size | Minimum Hose Internal Diameter (within 2 m) (Air Supply) | Minimum Hose Internal Diameter (within 2 m) (Vacuum) | Minimum Hose Internal Diameter (within 2 m) (Exhaustion) | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24,280,165 VND | 1 Piece(s) | 10 Day(s) | 35X10Nl/min | 10-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC110V | 35 | 60~65 dBA | 4 | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | 2 - Ø6.5 | >10 | >4 | 3/8"X2 | 363 | ||
31,511,880 VND | 1 Piece(s) | 10 Day(s) | 35X10Nl/min | 10-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC110V | 35 | 60~65 dBA | 4 | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | 2 - Ø6.5 | >10 | >4 | 3/8"X2 | 363 | ||
28,663,020 VND | 1 Piece(s) | 10 Day(s) | 35X10Nl/min | 10-layer | How to take out lead wire, Blinking light DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC110V | 35 | 60~65 dBA | 4 | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | 0.278 | 0.5 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | - | -85 kPa | 2 - Ø6.5 | >10 | >4 | 3/8"X2 | 363 | ||
13,560,050 VND | 1 Piece(s) | 10 Day(s) | 27X3Nl/min | 3-layer | How to take out lead wire, DIN type superconducting (without lead wire) | VITON material sealing | Air Control Valve, AC220V | 27 | 60~65 dBA | 2 | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | 2 - Ø3.4 | >2 | >2.5 | 3/8"X1 | 80 | ||
12,245,185 VND | 1 Piece(s) | 10 Day(s) | 27X3Nl/min | 3-layer | How to take out lead wire, DIN type superconducting (without lead wire) | NBR material | Air Control Valve, AC220V | 27 | 60~65 dBA | 4 | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | 2 - Ø3.4 | >2 | >2.5 | 3/8"X1 | 80 | ||
13,099,378 VND | 1 Piece(s) | 10 Day(s) | 27X3Nl/min | 3-layer | How to take out lead wire, DIN type superconducting (without lead wire) | EPDM material sealing | Air Control Valve, AC220V | 27 | 60~65 dBA | 4 | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | 0.556 | 1 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | - | -85 kPa | 2 - Ø3.4 | >2 | >2.5 | 3/8"X1 | 80 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy