(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Superior heat resistance: fluoropolymer tubing (PFA) metric size, TLM series.
[Features]
· Uses highly chemical-resistant fluoropolymer.
[Applications]
· Used in the manufacture of solar cells, liquid crystals, hard disk drives, and in the healthcare and food industries.
Fluoropolymer Tubing (PFA) Metric Size, TLM Series product images
Size | Metric Size | ||||||
---|---|---|---|---|---|---|---|
Nominal | TLM0201 | TLM0302 | TLM0425 | TLM0403 | TLM0604 | TLM0806 | TLM1075 |
Tube Size | ø2 (diameter: 2 mm) × ø1 (diameter: 1 mm) | ø3 (diameter: 3 mm) × ø2 (diameter: 2 mm) | ø4 (diameter: 4 mm) × ø2.5 (diameter: 2.5 mm) | ø4 (diameter: 4 mm) × ø3 (diameter: 3 mm) | ø6 (diameter: 6 mm) × ø4 (diameter: 4 mm) | ø8 (diameter: 8 mm) × ø6 (diameter: 6 mm) | ø10 (diameter: 10 mm) × ø7.5 (diameter: 7.5 mm) |
Outer Diameter (mm) | 2 | 3 | 4 | 4 | 6 | 8 | 10 |
Inner Diameter (mm) | 1 | 2 | 2.5 | 3 | 4 | 6 | 7.5 |
Size | Metric Size | |||||
---|---|---|---|---|---|---|
Nominal | TLM1008 | TLM1209 | TLM1210 | TLM1613 | TLM1916 | TLM2522 |
Tube Size | ø10 (diameter: 10 mm) × ø8 (diameter: 8 mm) | ø12 (diameter: 12 mm) × ø9 (diameter: 9 mm) | ø12 (diameter: 12 mm) × ø10 (diameter: 10 mm) | ø16 (diameter: 16 mm) × ø13 (diameter: 13 mm) | ø19 (diameter: 19 mm) × ø16 (diameter: 16 mm) | ø25 (diameter: 25 mm) × ø22 (diameter: 22 mm) |
Outer diameter (mm) | 10 | 12 | 12 | 16 | 19 | 25 |
Inner diameter (mm) | 8 | 9 | 10 | 13 | 16 | 22 |
Winding Length | Color | Symbol | TLM0201 | TLM0302 | TLM0425 | TLM0403 | TLM0604 | TLM0806 | TLM1075 | |
---|---|---|---|---|---|---|---|---|---|---|
Roll | 10 m | Translucent | N | - | - | - | - | - | - | ● |
20 m | Translucent | N | ● | ● | ● | ● | ● | ● | ● | |
Red (Translucent) | R | ● | ● | ● | ● | ● | ● | ● | ||
Blue (Translucent) | BU | ● | ● | ● | ● | ● | ● | ● | ||
Black (Opaque) | B | ● | ● | ● | ● | ● | ● | ● | ||
50 m | Translucent | N | ● | ● | ● | ● | ● | ● | ● | |
100 m | Translucent | N | ● | ● | ● | ● | ● | ● | ● | |
Straight Pipe | 2 m | Translucent | N | ● | ● | ● | ● | ● | ● | ● |
Winding Length | Color | Symbol | TLM1008 | TLM1209 | TLM1210 | TLM1613 | TLM1916 | TLM2522 | |
---|---|---|---|---|---|---|---|---|---|
Roll | 10 m | Translucent | N | ● | ● | ● | ● | ● | - |
20 m | Translucent | N | ● | ● | ● | ● | ● | ● | |
Red (Translucent) | R | ● | ● | ● | ● | ● | ● | ||
Blue (Translucent) | BU | ● | ● | ● | ● | ● | ● | ||
Black (Opaque) | B | ● | ● | ● | ● | ● | ● | ||
50 m | Translucent | N | ● | ● | ● | ● | ● | ● | |
100 m | Translucent | N | ● | ● | ● | ● | ● | - | |
Straight Pipe | 2 m | Translucent | N | ● | ● | ● | ● | ● | ● |
Working FluidsNote 1, Note 2, Note 3 and Applicable FittingsNote 1, Note 2, Note 3 | Fitting: Fluoropolymer fittings LQ Series | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fluids: air, water, inert gas; fittings: Single-action fittings KQ2, KQG2, KQB2; clean single-action fittings KP, KP□; Insert fittings KF, KFG2; miniature fittings M, MS (hose nipple type) | ||||||||||||||
Maximum Operating Pressure (MPa) | Please refer to the maximum operating pressure curve. | |||||||||||||
Minimum Bending Radius mm Note 4 | Recommended Radius | 10 | 20 | 20 | 35 | 35 | 60 | 95 | 100 | 100 | 130 | 160 | 220 | 400 |
Tube Close Bend Radius | 7 | 15 | 15 | 20 | 20 | 40 | 60 | 65 | 65 | 110 | 130 | 160 | 290 | |
Maximum Operating Temperature | 260°C | |||||||||||||
Material | PFA (tetrafluoroethylene, perfluoroalkoxy ethylene copolymer resin) |
Note 1: Please be aware that different fittings are appropriate for different fluids.
Note 2: When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 3: Do not use this product without the tubing affixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. Deterioration of materials due to extended use or exposure to high temperatures can lead to the development of leaks and other defects. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 4: The minimum bending radius is measured as shown in the figure below.
How to measure the minimum bending radius
Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformation ratio of the tubing outer diameter at bending reaches 5%.
Maximum operating pressure curve
Group | Model | Maximum Operating Pressure (MPa) | |||
---|---|---|---|---|---|
20°C | 100°C | 200°C | 260°C | ||
A | TLM0201 | 2.3 | 1.1 | 0.55 | 0.3 |
B | TLM0425 | 1.7 | 0.9 | 0.45 | 0.23 |
C | TLM0302 | 1.5 | 0.7 | 0.35 | 0.2 |
TLM0604 | |||||
D | TLM0403 | 1 | 0.5 | 0.25 | 0.15 |
TLM0806 | |||||
TLM1075 | |||||
TLM1209 | |||||
E | TLM1008 | 0.7 | 0.35 | 0.17 | 0.11 |
TLM1613 | |||||
F | TLM1210 | 0.6 | 0.3 | 0.15 | 0.1 |
TLM1916 | |||||
G | TLM2522 | 0.4 | 0.2 | 0.1 | 0.05 |
Example model number
Note: Tubing length will vary for each size. Please refer to the "series table."
Part Number |
---|
TLM1075N-20 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Outer Dia. D (Ø) | O.D. [Distinction] | Inner Dia. d (Ø) | I.D. [Distinction] | Color | Number of Cables (Core) | Minimum Bending Radius (mm) | Maximum operating pressure (MPa) | Operating temperature (°C) | Length (m) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7,832,800 VND | 1 Piece(s) | 32 Day(s) | 10 | ~10 | 7.5 | ~8 | [Transparent (including non-white colors)] Translucent (Material Color) | 1 | 95 | 1 (at 20°C) | Maximum operating temperature: 260°C | 20 |
Loading...Tải…
Type | Straight | Cutting Service Usage | No | Material | Fluororesin |
---|---|---|---|---|---|
Applicable Fluid | Water / Air / Chemical | Operating Environment | Standard / Heat resistant / Chemical Resistance | Material, Fluororesin | PFA ( tetrafluoroethylene, perfluoroalkoxy ethylene copolymer resin) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy