(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
2-Color Display Digital Pressure Sensor Controller PSE300 Series with auto-shift.
[Features]
· Auto-preset function / Display value calibration function / Peak hold and display function.
· Keylock function / Zero-clear function / Error display function / Unit switching function / Anti-chattering function.
2-Color Display Digital Pressure Sensor Controller PSE300 Series product image (1)
2-Color Display Digital Pressure Sensor Controller PSE300 Series product image (2)
Model number example
Model | PSE3□□ | ||||||
---|---|---|---|---|---|---|---|
Applicable pressure sensors | PSE533 PSE543 PSE563 PSE573 | PSE531 PSE541 PSE561 | PSE532 | PSE530 PSE540 PSE560 PSE570 | PSE564 PSE574 | PSE550 | |
Display / Set pressure (differential pressure) range | -101 to 101 kPa | -10 to 101 kPa | -10 to 101 kPa | -0.1 to 1 MPa | -50 to 500 kPa | -0.2 to 2 kPa | |
Display / Set resolution | 0.2 kPa | 0.1 kPa | 0.1 kPa | 0.001 MPa | 1 kPa | 0.01 kPa | |
Pressure range settingNote 1) | For compound pressure | For vacuum pressure | For low pressure | For positive pressure | For low differential pressure | ||
Rated pressure (differential pressure) range | -100 to 100 kPa | 0 to -101 kPa | 0 to 100 kPa | 0 to 1 MPa | 0 to 500 kPa | 0 to 2 kPa | |
Extended analog output rangeNote 2) | - | 10.1 to 0 kPa | -10 to 0 kPa | -0.1 to 0 MPa | -50 to 0 kPa | -0.2 to 0 kPa | |
Power supply voltage | 12 to 24 V DC ±10%, Ripple (p-p) 10% or less (with reverse connection protection) | ||||||
Current Consumption | 50 mA or less (Current consumption for sensor is not included) | ||||||
Sensor input | - | PSE30□: Voltage input 1 to 5 V DC (Input impedance: 1 MΩ) PSE31□: Current input 4 to 20 mA DC (Input impedance: 100 Ω) | |||||
Number of inputs | 1 input | ||||||
Input protection | With excess voltage protection (Up to 26.4 V) | ||||||
Hysteresis | Hysteresis mode: variable, Window comparator mode: variable | ||||||
Switch output | - | NPN or PNP open collector output, 2 outputs | |||||
Max Load Current | 80 mA | ||||||
Maximum load voltage | 30 V DC (at NPN output) | ||||||
Residual Voltage | 1 V or less (with load current of 80 mA) | ||||||
Output protection | With short-circuit protection | ||||||
Response time | - | 1 ms or less | |||||
Anti-chattering function | Response time settings for anti-chattering function: 20 ms, 160 ms, 640 ms, 1,280 ms | ||||||
Repeat accuracy | ±0.1% F.S. | ||||||
Analog Output | Voltage outputNote 2) | Output voltage: 1 to 5 V (within rated pressure [differential pressure] range), 0.6 to 1 V (within extended analog output range), Output impedance: approx. 1 kΩ, Linearity: ±0.2% F.S. (not including sensor accuracy), Response speed: 150 ms or less | |||||
Accuracy (to display value) (25°C) | ±0.6% F.S. | ±1.0% F.S. | ±1.5% F.S. | ||||
Current outputNote 2) | Output current: 4 to 20 mA (within rated pressure [differential pressure] range), 2.4 to 4 mA (within extended analog output range), Maximum load impedance: 300 Ω (at 12 V DC), 600 Ω (at 24 V DC), Minimum load impedance: Output impedance: 50 Ω, Linearity: ±0.2% F.S. (not including sensor accuracy), Response time: 150 ms or less | ||||||
Accuracy (to display value) (25°C) | ±1.0% F.S. | ±1.5% F.S. | ±2.0% F.S. | ||||
Display accuracy (ambient temperature of 25°C) | ±0.5% F.S. ±2 digits | ±0.5% F.S. ±1 digit | |||||
Display Method | 3 + 1/2 digit 7-segment indicator, 2-color display (red/green), Sampling frequency: 5 times / sec | ||||||
Status LEDs | OUT1: Lights up when output is turned ON (green), OUT2: Lights up when output is turned ON (red) | ||||||
Auto-shift inputNote 2) | Non-voltage input (reed or solid state), Low level input 5 ms or more, Low level 0.4 V or less | ||||||
Environmental resistance | Enclosure | IP40 | |||||
Operating temperature range | During operation: 0 to 50°C, During storage: -10 to 60°C (No freezing or condensation) | ||||||
Operating Humidity Range | During operation, storage: 35 to 85% RH (No condensation) | ||||||
Withstand Voltage | 1,000 V AC for 1 min. between terminals and housing | ||||||
Insulation Resistance | 50 MΩ or more (500 V DC, measured via megohmmeter) between terminals and housing | ||||||
Temperature characteristics | ±0.5% F.S. (25°C reference) | ||||||
Connection | PSE3□□: Power supply / output connection: 5P connector, Sensor connection: 4P connector, PSE3□□T: Terminal block | ||||||
Material | Front case: PBT, Rear case: PBT (PSE3□□), modified PPE (PSE3□□T) | ||||||
Weight | Including power supply / output connection cable | PSE3□□: 85 g | |||||
Not including power supply / output connection cable | PSE3□□: 30 g, PSE3□□T: 50 g | ||||||
Power supply / Output connection cable | Oilproof heavy-duty vinyl cable, 5 cores ø4.1 (4.1 mm diameter) 2 m, Conductor area: 0.2 mm2 Insulator O.D.: 1.12 mm | ||||||
Standard | CE UL/CSA (E216656) |
Note 1) Pressure range can be selected during initial setting.
Note 2) Auto-shift input function is not available when analog output is selected. Similarly, analog output function is not available when auto-shift function is selected.
Note 3) The following units can be selected with the display unit switching function.
1 to 5 V DC / 4 to 20 mA DC
Range | Rated pressure range | A | B | E |
---|---|---|---|---|
For vacuum pressure | 0 to -101 kPa | 0 | -101 kPa | 10.1 kPa |
For compound pressure | -100 kPa to 100 kPa | -100 kPa | 100 kPa | - |
For low pressure | 0 to 100 kPa | 0 | 100 kPa | -10 kPa |
For positive pressure | 0 to 1 MPa | 0 | 1 MPa | -0.1 MPa |
0 to 500 kPa | 0 | 500 kPa | -50 kPa |
Range | Rated pressure range | C | D | F |
---|---|---|---|---|
For low differential pressure | 0 to 2 kPa | 0 | 2 kPa | -0.2 kPa |
PSE3□0(T)-□□□□ / PSE3□1(T)-□□□□
(Unit: mm)
PSE3□□ dimensional diagram
(Unit: mm)
PSE3□□T dimensional drawing
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Type | Sensor, Monitor Structure | Operating Temperature Range (°C) | Operating Humidity Range (%) | Number of Input Points | Power Supply Type | Power Supply Voltage (V) | Mounting Holes | Display | Drive Component | Lamp | Acquired Standards | Protection Structure | Unit Specifications | Details Type | Accessory | Option | Input/output specifications | Input specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6,005,000 VND | 1 Piece(s) | 32 Day(s) | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + 1 to 5 V output | Voltage input | ||
6,133,000 VND | 1 Piece(s) | 32 Day(s) | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 1 to 5 V output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 4 to 20 mA output | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | PNP2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + auto shift input | Voltage input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + 4 to 20 mA output | Current Input | ||
6,183,000 VND | 1 Piece(s) | 32 Day(s) | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 4 to 20 mA output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + 4 to 20 mA output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + 4 to 20 mA output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | NPN2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | NPN2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | NPN2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | NPN2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 1 to 5 V output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + 4 to 20 mA output | Current Input | ||
6,183,000 VND | 1 Piece(s) | 32 Day(s) | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 4 to 20 mA output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + 4 to 20 mA output | Current Input | ||
6,183,000 VND | 1 Piece(s) | 32 Day(s) | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + 4 to 20 mA output | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | With unit conversion function | DIN rail / terminal block type | - | None | PNP2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | None | PNP2 output + auto shift input | Current Input | ||
- | 1 Piece(s) | Quote | - | Pressure Controller | Separate Type, Terminal Block Connection | - | 35~85 | 1 | DC | [12~24] 12 to 24 ±10% | No | Digital | Digital | Presence | CE | IP40 | SI unit fixed | DIN rail / terminal block type | - | Protective front cover | PNP2 output + auto shift input | Current Input |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy