(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Gap checker for at-a-glance checking of whether the workpiece is placed correctly or not.
[Features]
· Without control unit.
· Allows you to intuitively know how much of a gap there is between the workpiece and the detecting surface.
· Allows you to change the settings and see the values change on the display.
· Energy-saving type, with air consumption reduced by 60%.
· Drainage resistance increased by 10 times or more.
[Applications]
· Checking the reference plane for the press fitting of shafts, confirmation of close contact with the reference plane for machining, and confirmation of close contact with the workpiece for machining.
Digital Gap Checker, 3-Color Display, Without Control Unit, ISA3 Series: external appearance
Piping specification: C type structural diagram
Piping specification: F type structural diagram
*ISO1179-1 compliant
Model | ISA3-F | ISA3-G | ISA3-H | |||
---|---|---|---|---|---|---|
Applicable fluid | Dry air (filtered through a 5‑μm filter) | |||||
OUT1 OUT2*5 | Rated distance range | 0.01 to 0.03 mm | 0.02 to 0.15 mm | 0.05 to 0.30 mm | ||
Displayable/settable range (distance reference) *1 | 0 to 60 *2 | 10 to 300*2 | 30 to 500*2 | |||
Minimum display resolution (distance reference)*1 | 1 | |||||
Rated pressure range | 100 to 200 kPa | |||||
Displayable range (pressure value) *3 | -20 to 220 kPa | |||||
Repeatability | 0.005 mm or less | 0.010 mm or less | 0.020 mm or less | |||
Temperature characteristics (reference: 25°C) | 0.010 mm or less | 0.015 mm or less | 0.030 mm or less | |||
Hysteresis | 0 to variable (at factory setting: 3) | 0 to variable (at factory setting: 20) | ||||
OUT2 *6 | Rated pressure range | 0 to 200 kPa | ||||
Set pressure range | -20 to 220 kPa | |||||
Minimum display/setting resolution | 1 kPa | |||||
Repeatability | ±0.5% F.S. ±1 digit | |||||
Temperature characteristics (reference: 25°C) | ±2% F.S. | |||||
Hysteresis | Hysteresis mode | 0 to variable *7 | ||||
Window comparator mode | ||||||
Pressure resistance | 600 kPa | |||||
Detection nozzle | ø1.5 (diameter 1.5 mm) *4 | |||||
Consumption flow rate | 5 L/min or less | 12 L/min or less | 22 L/min or less | |||
Power supply voltage | 24 V DC ±10%, Ripple (p-p10% or less) (with power supply polarity protection) | |||||
Current consumption | 25 mA or less | |||||
Switch output | - | 1 output (NPN or PNP), 2 output (NPN or PNP) | ||||
Maximum load current | 10 mA | |||||
Maximum applied voltage | 26.4 V | |||||
Residual voltage | 1 V or less (at 10 mA) | |||||
Short-circuit protection | Equipped | |||||
Display system | 2-screen display LCD Main screen: 3-digit 7-segment, 2-color display (orange/green) Sub-screen: 6-digit 7-segment, 1-color display (white) | |||||
Environmental resistance | Enclosure | IP67 equivalent | ||||
Operating temperature range | When operating: 0 to 50°C , When stored: -20 to 70°C (no condensation and no freezing) | |||||
Operating humidity range | When operating/stored: 35 to 85% RH (no condensation) | |||||
Withstand voltage | 1,000 V AC or more (at 50/60 Hz) for 1 minute, between terminals and housing | |||||
Insulation resistance | 2 MΩ or more (500 V DC by megohmmeter) between terminals and housing | |||||
Piping specifications | If piping specifications are C | Supply port | Rc 1/8 | |||
Detection port | ø4 (diameter 4 mm) one-touch fitting | ø6 (diameter 6 mm) single-action fitting | ||||
If piping specifications are F | Supply port | G1/8 (ISO1179-1 compliant) | ||||
Detection port | G1/8 (ISO1179-1 compliant) | |||||
Cable | Lead wire with connector | M12 lead wire with 4 pin connector, 4 cores, ø4 (diameter 4 mm), 5 m Conductor outer diameter: 0.72 mm, Insulator outer diameter: 1.14 mm | ||||
Centralized lead wire | M12 lead wire with 4 pin connector, 4 cores, ø4 (diameter 4 mm), insulator outer diameter: 1.14 mm Centralized lead wire part: 2 to 3 stations, 5 cores, ø4 (diameter 4 mm), 5 m; 4 to 6 stations: 8 cores, ø6 (diameter 6 mm), 5 m Conductor outer diameter: 0.50 mm, Insulator outer diameter: 1.00 mm (2 to 6 stations common) | |||||
Weight | 113 g (for one-touch fitting, not including cable) | |||||
Standard | CE |
(Unit: mm)
ISA3-□□ (bracket mounted): dimensional drawings
*: ISO1179-1 compliant
L1 dimensions
Stations / 1: 38 mm, 2: 76 mm, 3: 114 mm, 4: 152 mm, 5: 190 mm, 6: 228 mm
H Dimension
Piping specification / C ø4 (diameter 4 mm), One-touch fitting: 13 mm, C ø6 (diameter 6 mm), One-touch fitting: 13.6 mm, F (G thread): 19 mm
With centralized lead wire: dimensional drawing
Pin no.
Pin name
ISA3-□□ (DIN rail mounted): dimensional drawings
*: ISO1179-1 compliant
With centralized lead wire: dimensional drawing
Pin no.
Pin name
Number of stations | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
L1 | 38 | 76 | 114 | 152 | 190 | 228 |
L2 | 62.5 | 125 | 162.5 | 200 | 237.5 | 275 |
L3 | 73 | 135.5 | 173 | 210.5 | 248 | 285.5 |
H Dimension
ISA3 Series (without control unit): structural diagram
Part Number |
---|
ISA3-HCP-M5B |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Number of stations | Option | Detection distance (mm) | Piping specifications | Output specifications | Unit specification for pressure values | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | 5 stations | With Bracket | 0.05 to 0.30 | Supply side (Rc1/8), detection side (ø6 one-touch) | PNP 1 output | SI unit fixed | Straight cable |
Loading...Tải…
Please check the type/dimensions/specifications of the part ISA3-HCP-M5B in the Digital Gap Checker, 3-Color Display, Without Control Unit, ISA3 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần ISA3-HCP-M5B trong chuỗi Digital Gap Checker, 3-Color Display, Without Control Unit, ISA3 Series.
Part Number |
---|
ISA3-FCB-1N |
ISA3-FCB-M1 |
ISA3-FCB-M2 |
ISA3-HCP-M6B |
ISA3-HFA-M1 |
ISA3-HFB-1N |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Number of stations | Option | Detection distance (mm) | Piping specifications | Output specifications | Unit specification for pressure values | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | 1 station | No bracket | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | PNP 2 output | With unit switching function | None | ||
- | 1 Piece(s) | Quote | 10 | 1 station | No bracket | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | PNP 2 output | SI unit fixed | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | 2 stations | No bracket | 0.01 to 0.03 | Supply side (Rc1/8), detection side (ø4 single-action) | PNP 2 output | SI unit fixed | Straight cable | ||
- | 1 Piece(s) | Quote | - | 6 stations | With Bracket | 0.05 to 0.30 | Supply side (Rc1/8), detection side (ø6 one-touch) | PNP 1 output | SI unit fixed | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | 1 station | No bracket | 0.05 to 0.30 | Supply side (G1/8), detection side (G1/8) | NPN 2 output | SI unit fixed | Straight cable | ||
- | 1 Piece(s) | Quote | 10 | 1 station | No bracket | 0.05 to 0.30 | Supply side (G1/8), detection side (G1/8) | PNP 2 output | With unit switching function | None |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy