(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
A vacuum regulator with cable connections available in 2 directions.
[Features]
· Stepless control of air pressure proportional to an electrical signal.
· Compact and lightweight (integrated communications).
· Sensitivity: 0.2% F.S. or less.
· Linearity: ±1% F.S. or less / hysteresis: 0.5% F.S. or less.
· Grease-free specifications.
· IP65.
[Applications]
· For analog control of multistage control or electrostatic coating control.
Electronic Vacuum Regulator ITV2090/2091 Series external appearance
Model | ITV2090 | ITV2091 | |
---|---|---|---|
Minimum Supply Vacuum Pressure Note 1: | Set pressure -13.3 kPa | ||
Maximum Supply Vacuum Pressure | -101 kPa | ||
Set Pressure Range | -1.3 to -80 kPa | ||
Power Supply | Voltage | 24 V DC ±10% | 12 to 15 V DC |
Current Consumption | Power supply voltage 24 V DC type: 0.12 A or less Note 7: Power supply voltage 12 to 15 V DC type: 0.18 A or less | ||
Input Signal Note 7: | Current Type Note 2: | 4 to 20 mA DC, 0 to 20 mA DC (sink type) | |
Voltage Type | 0 to 5 V DC, 0 to 10 V DC | ||
Preset Input | 4 points (negative common), 16 points (no common polarity) | ||
Digital Input | 10 bit (parallel) | ||
Input Impedance | Current Type | 250 Ω or less Note 3: | |
Voltage Type | Approx. 6.5 k Ω | ||
Preset Input | Power supply voltage 24 V DC type: approx. 4.7 k Ω Power supply voltage 12 V DC type: approx. 2.0 k Ω | ||
Digital Input | Approx. 4.7 k Ω | ||
Output Signal Note 4: (Monitor Output) | Analog Output | 1 to 5 V DC (output impedance: approx. 1 kΩ) 4 to 20 mA DC (sink type) (output impedance: 250 Ω or less) Output accuracy ±6% F.S. or less | |
Switch Output | NPN open collector output: maximum 30 V, 80 mA PNP open collector output: maximum 80 mA | ||
Linearity | ±1% F.S. or less | ||
Hysteresis | 0.5% F.S. or less | ||
Repeatability | ±0.5% F.S. or less | ||
Sensitivity | 0.2% F.S. or less | ||
Temperature Characteristics | ±0.12% F.S. / °C or less | ||
Output Pressure Display | Accuracy | ±2% F.S. ±1 digit or less | |
Units | kPa Note 5: minimum display: 1 | ||
Ambient And Fluid Temperature | 0 to 50°C (no condensation) | ||
Enclosure | IP65 | ||
Weight Note 7: Note 8: | 390 g |
Note 1: For the minimum supply vacuum pressure, supply a vacuum pressure 13.3 kPa lower than the set maximum vacuum pressure.
Note 2: Two-wire type 4 to 20 mA DC is not available. Power supply voltage (24 V DC or 12 to 15 V DC) is required.
Note 3: Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 350 Ω or less for an input current of 20 mA DC. When measuring ITV analog output from 1 to 5 V DC, if the load impedance is less than 100 kΩ, an analog monitor output accuracy of within ±6% (full span) may not be achievable. If an accuracy within ±6% is required, contact the manufacturer for further assistance. Output pressure remains unaffected.
Note 4: Select either analog output or switch output. When switch output is selected, select either NPN output or PNP output. Note that the preset input type does not have an output signal function.
Note 5: Contact the manufacturer for other pressure unit displays.
Note 6: The above characteristics are confined to the static state. When air is consumed on the output side, the pressure may fluctuate.
Note 7: Refer to the table below for communication specifications.
Note 8: Add 50 g for the digital input type, and 70 g for the 16-point preset input type.
Wiring diagram
Example with analog control for multistage control
Example with electrostatic coating control
Model | ITV□0□0-CC□□ | ITV□0□0-DE□□ | ITV□0□0-PR□□ | ITV□0□0-RC□□ | |
---|---|---|---|---|---|
Protocol Name | CC-Link | DeviceNet | PROFIBUS DP | RS-232C | |
Version Note 1: | Ver 1.10 | Volume 1 (Edition 3.8) Volume 3 (Edition 1.5) | DP-V0 | - | |
Communication Speed | 156 k / 625 k 2.5 M / 5 M / 10 M bps | 125 k / 250 k / 500 k bps | 9.6 k / 19.2 k / 45.45 k 93.75 k / 187.5 k / 500 k 1.5 M / 3 M / 6 M / 12 M bps | 9.6 kbps | |
Configuration File Note 2: | - | EDS | GSD | - | |
I/O Occupation Area (Input/Output Data) | 4 word / 4 word, 32 bit / 32 bit (Per station, remote device station) | 16 bit / 16 bit | 16 bit / 16 bit | - | |
Communication Data Resolution | 12 bit (4,096 resolution) | 12 bit (4,096 resolution) | 12 bit (4,096 resolution) | 10 bit (1,024 resolution) | |
Fail Safe | HOLD Note 3: / CLEAR (Switch setting) | HOLD/CLEAR (Switch setting) | CLEAR | HOLD | |
Electric Insulation Note 4: | Insulation | Insulation | Insulation | Non-insulated | |
Terminating Resistor | Built into the product (switch setting) | Not built into the product | Built into the product (switch setting) | - | |
Current Consumption | 0.16 A or less | 0.14 A or less | 0.16 A or less | 0.12 A or less | |
Weight | ITV2090 | 470 | 460 | 490 | 460 |
Note 1: Note that version information is subject to change.
Note 2: Check each file from the product documentation and instruction manual.
Note 3: The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data.
Note 4: Indicates the insulation between the electrical signal of the communication system and the ITV power supply.
(Unit: mm)
ITV209□ flat bracket dimensional drawing
L-bracket dimensional drawing
Right angle type (4-core) / 3‑m cable connector dimensional drawing
Straight type (4-core) / 3‑m cable connector dimensional drawing
Note: The cable connector cannot be rotated. Do not try to rotate it.
ITV2090/2091 Series operating principle diagram
When the input signal rises, the vacuum pressure solenoid valve (1) turns ON and the atmospheric pressure solenoid valve (2) turns OFF.
Therefore, pressure in the pilot chamber (3) becomes negative pressure through VAC. and the pilot chamber, which operates on the upper portion of the diaphragm (4).
As a result, the vacuum pressure valve (5) linked to the diaphragm (4) opens, and the set pressure becomes negative pressure through VAC. and OUT.
This negative pressure feeds back to the control circuit (8) via the pressure sensor (7).
Here, pressure corrections continue until the vacuum pressure becomes proportional to the input signal, thus supplying vacuum pressure that is consistently proportional to the input signal.
ITV2090/2091 Series block diagram
Part Number |
---|
ITV2090-31N2BS5 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Supply Side, Connection Type | Control Side, Connection Type | Input Signal | Cable connector | Communication signal | Monitor output | Bracket | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
12,547,000 VND | 1 Piece(s) | 32 Day(s) | - | NPT | NPT | DC 0-10V | Straight type 3 m | Voltage type 0 to 10 V DC | Analog output 1 to 5 V DC | Flat-bracket | 24 V DC |
Loading...Tải…
Type | Electronic Electropneumatic Regulator | Control Method | Internal Pilot | Shape | Standard |
---|---|---|---|---|---|
Supply Side, Plumbing Thread Nominal | 1/4 | Control Side, Plumbing Thread Nominal | 1/4 | Set Pressure Range(kPa) | -1.3::-80 |
Please check the type/dimensions/specifications of the part ITV2090-31N2BS5 in the Electronic Vacuum Regulator ITV2090/2091 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần ITV2090-31N2BS5 trong chuỗi Electronic Vacuum Regulator ITV2090/2091 Series.
Part Number |
---|
ITV2090-012CL5 |
ITV2090-012CN5 |
ITV2090-012CS5 |
ITV2090-31N2CL5 |
ITV2090-31N2CN5 |
ITV2090-31N2CS5 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Supply Side, Connection Type | Control Side, Connection Type | Input Signal | Cable connector | Communication signal | Monitor output | Bracket | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | Rc(R) | Rc(R) | DC 4-20mA | Right angle type 3 m | Current type 4 to 20 mA DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC | ||
- | 1 Piece(s) | Quote | - | Rc(R) | Rc(R) | DC 4-20mA | Without cable connector | Current type 4 to 20 mA DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC | ||
12,547,000 VND | 1 Piece(s) | 32 Day(s) | - | Rc(R) | Rc(R) | DC 4-20mA | Straight type 3 m | Current type 4 to 20 mA DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC | ||
12,547,000 VND | 1 Piece(s) | 32 Day(s) | - | NPT | NPT | DC 0-10V | Right angle type 3 m | Voltage type 0 to 10 V DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC | ||
- | 1 Piece(s) | Quote | - | NPT | NPT | DC 0-10V | Without cable connector | Voltage type 0 to 10 V DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC | ||
12,547,000 VND | 1 Piece(s) | 32 Day(s) | - | NPT | NPT | DC 0-10V | Straight type 3 m | Voltage type 0 to 10 V DC | Analog output 1 to 5 V DC | L-bracket | 24 V DC |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy