(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Air cylinder with auto switch (built-in magnet).
[Features]
· Air consumption reduced by up to 29% thanks to optimal size selection.
· Reduces labor time: no air cushion adjustment required thanks to non-adjustable air cushion.
· RoHS compliant.
· Mounting: basic type.
· Port thread types: Rc, NPT, G.
· *Not available without magnet.
Model Number Notation
JMB Series Air Cylinder, Double Acting, Single Rod external appearance 1
JMB Series Air Cylinder, Double Acting, Single Rod external appearance 2
Action | Double acting, single rod |
---|---|
Fluid | Air |
Proof Pressure | 1.0 MPa |
Maximum operating pressure | 0.7 MPa*1 |
Minimum operating pressure | 0.05 MPa |
Ambient and Fluid Temperature | 5 to 60°C |
Lubrication | Not required (non-lubricated) |
Piston speed* | 50 to 500 mm/s*1 |
Stroke Length Tolerance | 0 to 2 |
Cushioning | Non-adjustable air cushion + rubber bumper |
Connection Port Size (Rc, NPT, G) | 1/8 (bore size 32 mm / 40 mm / 45 mm / 50 mm / 56 mm), 1/4 (bore size 63 mm / 67 mm / 80 mm / 85 mm), 3/8 (bore size 100 mm) |
Mounting | Basic type |
*Depending on the system configuration selected, the specified speed may not be satisfied.
*1: The maximum operating pressure and piston speed differ from the MB Series.
Tube Inner Diameter (mm) | Standard Stroke (mm) | Max. manufacturable stroke |
---|---|---|
32 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 | 300 |
40 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 | 300 |
45 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 | 300 |
50 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 | 400 |
56 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 | 400 |
63 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 | 400 |
67 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 | 400 |
80 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 | 500 |
85 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 | 500 |
100 | 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 | 500 |
(Unit: kg)
Tube Inner Diameter (mm) | 32 | 40 | 45 | 50 | 56 | 63 | 67 | 80 | 85 | 100 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Basic weight | Basic type | 0.21 | 0.30 | 0.32 | 0.62 | 0.69 | 0.88 | 1.03 | 1.54 | 1.91 | 2.56 |
Additional weight per 50 mm of stroke | 0.11 | 0.17 | 0.18 | 0.19 | 0.20 | 0.20 | 0.24 | 0.32 | 0.38 | 0.46 |
Calculation
Example) JMDBB32-100 (Basic, ø32 [32‑mm diameter], 100 mm stroke)
0.21 + 0.11 × 100/50 = 0.43 kg
Allowable kinetic energy graph
Example) Find the upper limit of the rod-end load when an air cylinder of ø50 (50-mm diameter) is operated at 300 mm/s.
From a point indicating 300 mm/s on the horizontal axis, extend a line upward and find a point where it intersects with a line for the 50-mm bore size. Extend a line from the intersection to the left and find a load mass of 40 kg.
Graph of allowable lateral load at rod end
Dimensional drawings: JMDBB
(Units: mm)
Tube inner diameter (mm) | Stroke range (mm) | A | AL | B | B1 | C | D | E | F | G | H | H1 | J | K | KA | M | MM | N | P | S | ZZ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | Up to 300 | 22 | 19.5 | 42 | 17 | 31 | 10 | 24 | 8 | 9 | 38 | 6 | M5 × 0.8 | 5.5 | 8 | 8 | M10 × 1.25 | 18 | 1/8 | 63 | 109 |
40 | Up to 300 | 24 | 21 | 48 | 22 | 37 | 14 | 32 | 9 | 9 | 44 | 8 | M5 × 0.8 | 8 | 12 | 8 | M14 × 1.5 | 18 | 1/8 | 62 | 114 |
45 | Up to 300 | 24 | 21 | 52 | 22 | 41 | 14 | 32 | 9 | 9 | 44 | 8 | M5 × 0.8 | 8 | 12 | 8 | M14 × 1.5 | 18 | 1/8 | 62 | 114 |
50 | Up to 400 | 35 | 32 | 60 | 27 | 45 | 18 | 38 | 10 | 9 | 55 | 11 | M6 × 1 | 7 | 16 | 11 | M18 × 1.5 | 18 | 1/8 | 63 | 129 |
56 | Up to 400 | 35 | 32 | 65 | 27 | 50 | 18 | 38 | 10 | 9 | 55 | 11 | M6 × 1 | 7 | 16 | 11 | M18 × 1.5 | 18 | 1/8 | 63 | 129 |
63 | Up to 400 | 35 | 32 | 70 | 27 | 55 | 18 | 38 | 6 | 11 | 51 | 11 | M6 × 1 | 7 | 16 | 11 | M18 × 1.5 | 22 | 1/4 | 73 | 135 |
67 | Up to 400 | 35 | 32 | 75 | 27 | 58 | 18 | 38 | 6 | 11 | 51 | 11 | M8 × 1.25 | 7 | 16 | 11 | M18 × 1.5 | 22 | 1/4 | 73 | 135 |
80 | Up to 500 | 40 | 37 | 88 | 32 | 69 | 22 | 45 | 12 | 13 | 62 | 13 | M8 × 1.25 | 7 | 19 | 13 | M22 × 1.5 | 26 | 1/4 | 83 | 158 |
85 | Up to 500 | 40 | 37 | 95 | 32 | 74 | 22 | 45 | 12 | 13 | 62 | 13 | M10 × 1.25 | 7 | 19 | 14 | M22 × 1.5 | 26 | 1/4 | 83 | 159 |
100 | Up to 500 | 40 | 37 | 110 | 41 | 87 | 26 | 50 | 10 | 14 | 66 | 16 | M10 × 1.25 | 12 | 23 | 14 | M26 × 1.5 | 28 | 3/8 | 88 | 168 |
3-wire, NPN
2-wire
*Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications.
3-wire, PNP
2-wire
*Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications.
3-wire AND connection for NPN output (using relays)
*When using solid state auto switches, ensure the application is set up so the signals for the first 50 ms are invalid.
Part Number |
---|
JMDBB80TF-200 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Port thread type | Auto Switches | Lead Wire | The number of the switches |
---|---|---|---|---|---|---|---|---|---|---|
3,496,965 VND | 1 Piece(s) | 32 Day(s) | 80 | 200 | G | None | - | - |
Loading...Tải…
Cylinder Operation Method | Double Acting | Rod Operation Method | Single Rods | Main Body Shape | Plate Cylinder |
---|---|---|---|---|---|
Additional Function | Standard | Environment, Applications | Standard | Cushion | Non-adjustable air cushion + rubber bumper |
Operating Pressure(MPa) | 0.05 to 0.7 | Specifications | Built-in magnet | Type of Mount Support | Basic type |
Please check the type/dimensions/specifications of the part JMDBB80TF-200 in the JMB Series Air Cylinder, Double Acting, Single Rod series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần JMDBB80TF-200 trong chuỗi JMB Series Air Cylinder, Double Acting, Single Rod.
Part Number |
---|
JMDBB100-125-M9B |
JMDBB100-150 |
JMDBB100-155 |
JMDBB80TF-25 |
JMDBB80TF-250 |
JMDBB80TF-300 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Port thread type | Auto Switches | Lead Wire | The number of the switches |
---|---|---|---|---|---|---|---|---|---|---|
5,311,600 VND | 1 Piece(s) | 31 Day(s) | 100 | 125 | Rc | M9B | 0.5 | 2 | ||
5,649,000 VND | 1 Piece(s) | 32 Day(s) | 100 | 150 | Rc | None | - | - | ||
- | 1 Piece(s) | Quote | 100 | 155 | Rc | None | - | - | ||
- | 1 Piece(s) | Quote | 80 | 25 | G | None | - | - | ||
- | 1 Piece(s) | Quote | 80 | 250 | G | None | - | - | ||
- | 1 Piece(s) | Quote | 80 | 300 | G | None | - | - |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy