(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
A water-resistant air cylinder configured for easy cleaning.
[Features]
· Cylinder with improved water resistance and 5 times longer lifespan (compared to manufacturer's current models).
· With auto switch (HYDCB).
· To keep the product flat, grooves for auto switches and holes for cushion needles, etc. have been eliminated.
Model Number Notation
HYC Series ISO Standard Type Hygienic Design Cylinder external appearance
JIS symbol for HYC Series ISO Standard Type Hygienic Design Cylinder (air cushion)
Tube Inner Diameter (mm) | 32 | 40 | 50 | 63 |
---|---|---|---|---|
Action | Double acting, single rod | |||
Fluid | Air | |||
Minimum operating pressure | 0.15 MPa | |||
Maximum operating pressure | 1.0 MPa | |||
Proof Pressure | 1.5 MPa | |||
Ambient and Working Fluid Temperature | Without switch: 0°C to 70°C | |||
With switch: 0°C to 60°C | ||||
Lubrication | Not required | |||
Piston Speed | 50 to 500 mm/s (with pressure at 1.0 MPa)* | |||
Cushioning | Air cushion | |||
Stroke length tolerance | Up to 250 (0 to +1.0) mm, 251 to 600 mm (0 to +1.4) mm | |||
Piston rod material | SUS304 hard chrome plating |
*Use the product below the allowable kinetic energy. See the manufacturer's catalog for the allowable kinetic energy.
Tube Inner Diameter (mm) | Standard Stroke (mm) |
---|---|
32 | 25, 50, 75, 100, 125, 150, 200, 250, 300, 400, 500 |
40 | 25, 50, 75, 100, 125, 150, 200, 250, 300, 400, 500 |
50 | 25, 50, 75, 100, 125, 150, 200, 250, 300, 400, 500, 600 |
63 | 25, 50, 75, 100, 125, 150, 200, 250, 300, 400, 500, 600 |
Drawing: without auto switch, HYCB32 to 63
(Units: mm)
Tube inner diameter | Stroke range | A | AL | B | B1 | C | D | Ee11 | F | FA | FB | G | H | H1 | MA | MB |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | To 500 | 22 | 18 | 50 | 17 | 32.5 | 12 | 30 | 16 | 5 | 4 | 14 | 48 | 6 | 16 | 3.2 |
40 | To 500 | 24 | 20 | 58 | 19 | 38 | 16 | 35 | 18.5 | 4.5 | 4 | 15 | 54 | 7 | 16 | 3.2 |
50 | To 600 | 32 | 27 | 70 | 24 | 46.5 | 20 | 40 | 23 | 5 | 4 | 17 | 69 | 10 | 16 | 4.2 |
63 | To 600 | 32 | 27 | 84 | 24 | 56.5 | 20 | 45 | 23 | 5 | 4 | 17 | 69 | 10 | 16 | 4.2 |
Tube inner diameter | Stroke range | J | K | KA | MM | N | P | S | T | U | V | W | HA | ZZ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | To 500 | M6 × 1 | 6 | 10 | M10 × 1.25 | 28 | 1/8 | 94 | 62 | 21 | 6 | 6.5 | 30 | 146 |
40 | To 500 | M6 × 1 | 6.5 | 13 | M12 × 1.25 | 28 | 1/4 | 105 | 71 | 21 | 6 | 8.5 | 34 | 163 |
50 | To 600 | M8 × 1.25 | 8 | 16 | M16 × 1.5 | 32 | 1/4 | 106 | 88 | 25 | 8 | 11 | 40 | 179 |
63 | To 600 | M8 × 1.25 | 8 | 16 | M16 × 1.5 | 32 | 3/8 | 121 | 102 | 25 | 10 | 9 | 47 | 194 |
Note 1) See the manufacturer's catalog for details about the rod end nut, mounting bracket and accessory bracket.
Note 2) When the unit is installed, ensure that dirt does not collect in the rod end (threaded portion).
Drawing: with auto switch, HYDCB32 to 63
(Units: mm)
Tube inner diameter | Stroke range | A | AL | B | B1 | C | D | Ee11 | F | FA | FB | G | H | H1 | MA | MB | J |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | To 500 | 22 | 18 | 50 | 17 | 32.5 | 12 | 30 | 16 | 5 | 4 | 14 | 48 | 6 | 16 | 3.2 | M6 × 1 |
40 | To 500 | 24 | 20 | 58 | 19 | 38 | 16 | 35 | 18.5 | 4.5 | 4 | 15 | 54 | 7 | 16 | 3.2 | M6 × 1 |
50 | To 600 | 32 | 27 | 70 | 24 | 46.5 | 20 | 40 | 23 | 5 | 4 | 17 | 69 | 10 | 16 | 4.2 | M8 × 1.25 |
63 | To 600 | 32 | 27 | 84 | 24 | 56.5 | 20 | 45 | 23 | 5 | 4 | 17 | 69 | 10 | 16 | 4.2 | M8 × 1.25 |
Tube inner diameter | Stroke range | K | KA | MM | N | P | S | T | U | V | W | SA | SB | HS | HA | ZZ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | To 500 | 6 | 10 | M10 × 1.25 | 28 | 1/8 | 94 | 62 | 21 | 6 | 6.5 | 7.5 | 16.5 | 50 | 30 | 146 |
40 | To 500 | 6.5 | 13 | M12 × 1.25 | 28 | 1/4 | 105 | 71 | 21 | 6 | 8.5 | 12 | 23 | 54 | 34 | 163 |
50 | To 600 | 8 | 16 | M16 × 1.5 | 32 | 1/4 | 106 | 88 | 25 | 8 | 11 | 9 | 19 | 60 | 40 | 179 |
63 | To 600 | 8 | 16 | M16 × 1.5 | 32 | 3/8 | 121 | 102 | 25 | 10 | 9 | 19 | 24 | 67 | 47 | 194 |
Note 1) The [ ] value denotes dimensions of the built-in magnet type with the auto switch D-F6□ mounted.
Note 2) See the manufacturer's catalog for details about the rod end nut, mounting bracket and accessory bracket.
Note 3) When the unit is installed, ensure that dirt does not collect in the rod end (threaded portion).
Part Number |
---|
HYDCB40R-25F-F6B |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Specifications | Port thread type | Auto Switches | Lead Wire | The number of the switches | Sealing materials | Grease |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 40 | 25 | With built-in magnet and switch rail | Rc | F6B | 0.5 | 2 | NBR | Food compatible grease |
Loading...Tải…
Cylinder Operation Method | Double Acting | Rod Operation Method | Single Rods | Main Body Shape | Plate Cylinder |
---|---|---|---|---|---|
Environment, Applications | Standard | Cushion | Air cushion |
Please check the type/dimensions/specifications of the part HYDCB40R-25F-F6B in the HYC Series ISO Standard Type Hygienic Design Cylinder series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần HYDCB40R-25F-F6B trong chuỗi HYC Series ISO Standard Type Hygienic Design Cylinder.
Part Number |
---|
HYCB32H-125F |
HYCB32H-150F |
HYCB32H-210 |
HYDCB40R-27 |
HYDCB40R-30 |
HYDCB40R-300 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Specifications | Port thread type | Auto Switches | Lead Wire | The number of the switches | Sealing materials | Grease |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 32 | 125 | Without magnet | Rc | - | - | - | External FKM | Food compatible grease | ||
- | 1 Piece(s) | Quote | 32 | 150 | Without magnet | Rc | - | - | - | External FKM | Food compatible grease | ||
- | 1 Piece(s) | Quote | 32 | 210 | Without magnet | Rc | - | - | - | External FKM | Standard grease (for non-food) | ||
- | 1 Piece(s) | Quote | 40 | 27 | With built-in magnet and switch rail | Rc | None | - | - | NBR | Standard grease (for non-food) | ||
- | 1 Piece(s) | Quote | 40 | 30 | With built-in magnet and switch rail | Rc | None | - | - | NBR | Standard grease (for non-food) | ||
- | 1 Piece(s) | Quote | 40 | 300 | With built-in magnet and switch rail | Rc | None | - | - | NBR | Standard grease (for non-food) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy