(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
High-speed data logger unit that meets all logging needs without a personal computer.
[Features]
・ It achieves unprecedented accurate data logging with high speed, simplicity, and low cost
・ [High-speed collection function]It achieves data logging synchronized with sequence scan
・ [Trigger logging function]It achieves data logging synchronized with sequence scan
・ [Event logging function]It contributes to abnormality detection and failure prediction by grasping equipment abnormality in time series
・ External Dimensions: (H) 98 mm, (W) 27.4 mm, (D) 90 mm
Data Acquisition | Number of Accessed CPUs | Maximum 64 | |
---|---|---|---|
Acquisition Interval | High-Speed Acquisition | · Sequence Scan Time Synchronization · 1 to 32,767 ms (for trigger logging) · 3 to 32,767 ms (for continuous logging) | |
General-Purpose Acquisition | · 0.1 to 0.9 s, 1 to 32,767 s · Time interval specification (hour/minutes/seconds specification) | ||
Number of Acquired Data | High-Speed Acquisition | · Total number of data: max. 8,192 (256 per setting) · Total number of device points: max. 8,192 (256 per setting) | |
General-Purpose Acquisition | · Total number of data: maximum 16,384 (256 per setting) · Total number of device points: maximum 262,144 (4,096 per setting) | ||
Data Types | · Bit · Word (signed) · Double words (signed) · Word (unsigned) · Double words (unsigned) · Single-precision real number · Double-precision real number · 16-bit BCD · 32-bit BCD · Character string: 1 to 8,192 characters · Numerical string: 1 to 8,192 bytes | ||
Data Output Format (CSV File) | · Bit · Decimal: 0 to 14 decimal digits · Exponential: 0 to 14 decimal digits · Hexadecimal · Character string · Numerical string | ||
Scaling | Arithmetic operations: operations combining (×, /) and (+, -) | ||
Data Logging | Number of Settings | Maximum 64 | |
Logging Types | · Continuous logging · Trigger logging | ||
File Format | · CSV File (Extension: .CSV) · Binary File (Extension: .BIN) | ||
Period | Specify the applicable period or excluded period. · Data conditions: bit ON/OFF, comparison of data against a constant value, comparison of data against data · Date range: specification of starting and ending months/days · Time range: specification of starting and ending hour/minutes/seconds · Day of week / week conditions: specification of day of the week or a week AND or OR of the above: up to 8 conditions | ||
Trigger Logging | Trigger Conditions | · Condition: · Comparison: bit ON/OFF, comparison of data against a constant value, comparison of data against data · Change in value · Constant cycle: 1 to 86,400 s · Time interval specification: specification of hour/minutes/seconds · Time specification: specification of month/day/hour/minutes/seconds · Startup of unit AND or OR of the above (for up to 8 conditions). · Number of conditions established: 3 conditions · Condition establishment order (order and time condition): up to 4 conditions | |
Number of Logging Lines | · Before trigger: 0 to 65,534 lines · After trigger: 1 to 65,535 Up to 65,535 lines as a total of the above before and after trigger | ||
File Switching Timing | · Specification of number of lines (number of records): 100 to 100,000 lines · Specification of file size: 10 to 16,384 KB · Condition specification: · Comparison: bit ON/OFF, comparison of data against a constant value, comparison of data against data · Change in value · Constant cycle: 1 to 86,400 s · Time interval specification: specification of hour/minutes/seconds · Time specification: specification of month/day/hour/minutes/seconds · Startup of unit AND or OR of the above: up to 8 conditions · Trigger logging unit | ||
Number of Saved Files | 1 to 65,535 | ||
Report | Number of Settings | Maximum 64 | |
File Format | Excel® File (Extension: .xls) | ||
Output Data Types | · Data in the data logging file · Present value data · Time created | ||
Number of Output Data | 64 layouts per report setting, for total 65,535 cells | ||
Creation Trigger Conditions | · Condition: · Comparison: bit ON/OFF, comparison of data against a constant value, comparison of data against data · Change in value · Constant cycle: 1 to 86,400 s · Time interval specification: specification of hour/minutes/seconds · Time specification: specification of month/day/hour/minutes/seconds · Startup of unit · Data logging file switching AND or OR of the above (up to 8 conditions) · Number of conditions established: 3 conditions · Condition establishment order (order and time condition): up to 4 conditions | ||
Period | Specify the applicable period or excluded period. · Data conditions: bit ON/OFF, comparison of data against a constant value, comparison of data against data · Date range: specification of starting and ending months/days · Time range: specification of starting and ending hour/minutes/seconds · Day of week / week conditions: specification of day of the week or a week AND or OR of the above: up to 8 conditions | ||
Layout File Size | Maximum 10 M bytes (total of all report settings) | ||
Number of Saved Files | 1 to 65,535 | ||
Applications | · Event notification · Saved file transmission | ||
Subject | · Event notification email: user-specified · Saved file transmission email: automatically generated / user-specified | ||
Main Text | · Event notification email: user-specified · Saved file transmission email: automatically generated / user-specified | ||
Attachment File | · Event notification email: none · Saved file transmission email: saved file (CSV, binary, Excel file), maximum 512 K bytes | ||
Attachment File Format | MIME format | ||
MIME | Version 1.0 | ||
Communication With Mail Server | Port Number | 25, 587, Other (1 to 65,535) | |
Authentication Method | · No Authentication · SMTP-AUTH (PLAIN, LOGIN, CRAM-MD5) · POP before SMTP | ||
Recipient Address | Maximum 16 groups | ||
Validated Email Client Software | · Microsoft® Outlook® Express 6.0 · Microsoft® Windows® Mail 6.0 | ||
FTP Server | Applications | Read/delete saved files, write/read/delete recipe files | |
Validated FTP Client Software | · Microsoft® Internet Explorer® 6.0 · Windows® Internet Explorer® 7.0 · Windows® Internet Explorer® 8.0 · Windows® Internet Explorer® 9.0 · Windows® Internet Explorer® 10.0 · Windows® Internet Explorer® 11.0 | ||
Number of Sessions | 10 | ||
FTP Client | Applications | Saved file transfer | |
Validated FTP Server Software | Microsoft®Internet Information Service | ||
Recipe | Number of Data | Maximum 256 data | |
Number of Records | Maximum 256 records | ||
Data Types | · Bit · Word [signed] · Double words [signed] · Word [unsigned] · Double words [unsigned] · Single-precision real number · Double-precision real number · 16-bit BCD · 32-bit BCD | ||
Recipe File | CSV File (Extension: CSV) Maximum 256 files | ||
Execution Type | Dedicated commands (ladder programs), setting tools |
Ethernet Part | Interface | 10BASE-T/100BASE-TX | |
---|---|---|---|
Communication Method | Full-duplex / Half-duplex communication mode | ||
Flow Control | Full duplex communication: none (IEEE802.3x flow control is not supported) Half duplex communication: back pressure | ||
Data Transmission Speed | 10 Mbps(10BASE-T)/100 Mbps(100BASE-TX) | ||
Transmission Method | Baseband | ||
Number of Cascade Connection Levels | Maximum 4 levels (10BASE-T) / Maximum 2 levels (100BASE-TX) | ||
Maximum Segment Length | 100 m | ||
Support Function | Automatic negotiation function (Automatic recognition of communication speed / communication method) | ||
Compact Flash Card Part | Supplied Power Capacity | Maximum 150 mA | |
Card Size | TYPE I card | ||
Supplied Power Voltage | 3.3 V ±5% | ||
Installable Quantity | 1 pc. | ||
Number of Occupied Inputs/Outputs | 32 points (I/O assignment: intelligent 32 points) | ||
Clock | · Obtained from the sequencer CPU (first CPU unit in the case of a multi-CPU system) or SNTP server · Once the clock data is obtained, the clock has a daily variance of ±9.504 seconds | ||
5 V DC Internal Current Consumption | 0.50 A | ||
External Dimensions | Height (H) | 98 mm | |
Width (W) | 27.4 mm | ||
Depth (D) | 90 mm | ||
Weight | 0.15 kg |
Part Number |
---|
QD81DL96 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng |
---|---|---|---|---|
17,207,500 VND | 1 Piece(s) | Quote |
Loading...Tải…
Representative Standard | CE / UL | Number of Data Logging Settings | 64 | Collection Interval | Scan Data Synchronization, 1 to 32767 ms (Trigger Logging), 3 to 32767 ms (Continuous Logging), 0.1 to 0.9 s, 1 to 32767 s, Time Interval Setting |
---|---|---|---|---|---|
Transmitting specification standards | 10BASE-T/100BASE-TX |
Please check the type/dimensions/specifications of the part QD81DL96 in the MELSEC-Q Series High Speed Data Logger Unit series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần QD81DL96 trong chuỗi MELSEC-Q Series High Speed Data Logger Unit.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy