(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Enhancing production safety. A CC-Link Safety master unit for MELSEC-QS series.
QS0J61BT12 image
Transmission Speed | 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps (Selectable) | ||
---|---|---|---|
Maximum Total Cable Extension (Maximum Transmission Distance) | Ver. 1.10 | At 156 kbps | 1,200 m |
At 625 kbps | 900 m | ||
At 2.5 Mbps | 400 m | ||
At 5 Mbps | 160 m | ||
At 10 Mbps | 100 m | ||
Station Type | Safety master station | ||
Maximum Number of Connected Devices | 64 devices | ||
Maximum Link Points Per System | Remote inputs/outputs (RX, RY): 2,048 points Remote registers (RWr): 256 points Remote registers (RWw): 256 points | ||
Link Points Per Remote Station | Safety Remote Station | With One Station Occupied | Remote inputs (RX): 32 points Remote outputs (RY): 32 points Remote registers (RWw): 0 points Remote registers (RWr): 0 points |
General Remote Station | With One Station Occupied | Remote inputs (RX): 32 points Remote outputs (RY): 32 points Remote registers (RWw): 4 points Remote registers (RWr): 4 points | |
With Two Stations Occupied | Remote inputs (RX): 64 points Remote outputs (RY): 64 points Remote registers (RWw): 8 points Remote registers (RWr): 8 points | ||
With Three Stations Occupied | Remote inputs (RX): 96 points Remote outputs (RY): 96 points Remote registers (RWw): 12 points Remote registers (RWr): 12 points | ||
With Four Stations Occupied | Remote inputs (RX): 128 points Remote outputs (RY): 128 points Remote registers (RWw): 16 points Remote registers (RWr): 16 points | ||
Communication Method | Broadcast polling method | ||
Synchronization Method | Frame synchronization method | ||
Encryption Method | NRZI (Non Return to Zero Inverted) sign | ||
Transmission Path Type | Bus (RS-485) | ||
Transmission Format | HDLC-compliant | ||
Error Control Method | Safety Remote Station | CRC32 (X32 + X26 + X23 + X22 + X16 + X12 + X11 + X10 + X8 + X7 + X5 + X4 + X2 + X + 1) | |
General Remote Station | CRC (X16 + X12 + X5 + 1) | ||
Communication Cable | Dedicated CC-Link cable compatible with Ver. 1.10 Dedicated CC-Link cable (compatible with Ver. 1.00) Dedicated CC-Link high-performance cable (compatible with Ver. 1.00) | ||
Number of Occupied Inputs/Outputs | 32 points (I/O assignment: intelligent 32 points) | ||
5 V DC Internal Current Consumption | 0.46 A | ||
Weight | 0.12 kg |
Part Number |
---|
QS0J61BT12 |
QS0J61BT12-K |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Communication Interface (Transmission Standard) | Representative Standard | Type of unit | Transmission Speed | Maximum Number of Connected Devices |
---|---|---|---|---|---|---|---|---|---|
15,473,750 VND | 1 Piece(s) | Quote | - | CE / UL | CC-Link Safety Master Station | 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps | 64 unit | ||
18,327,500 VND | 1 Piece(s) | Quote | Other | CE / UL / CUL | - | - | - |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy