(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]
· Built-in CT, new concept SSR allows for heater disconnection detection and SSR short-circuit malfunction detection.
· Built-in CT, promotes reduction in wiring man-hours.
· Can detect single disconnection in multiple heaters.
· Can detect disconnection in 3-phase heaters.
· Can detect SSR short-circuit malfunctions.
· Abnormality detection level can be easily set by switch.
· Both DIN rail mounting and screw mounting are possible.
· 3 types of input terminals are available: M3 terminal, screwless clamp terminal (removable), and small minus terminal (removable).
· CSA standards, EN standards (TÜV certification) acquired.
· UL standard acquired (model G3PF-2□□B-□□□ series).
G3PF-225B external appearance
G3PF-225B dimensional outline drawing, Units: mm
G3PF-225B dimensional outline drawing, Units: mm
Mounting hole dimensions, Units: mm
G3PF-235B external appearance
G3PF-235B dimensional outline drawing, Units: mm
G3PF-235B dimensional outline drawing, Units: mm
G3PF-235B mounting hole dimensions, Units: mm
Rated Power Supply Voltage | 24 V DC |
---|---|
Operating Voltage Range | 20.4 to 26.4 V DC |
Current Consumption | DC 50 mA max. (at 24 V DC) |
Input Method | Voltage Input |
---|---|
Rated Input Voltage | 12 to 24 V DC |
Operating Input Voltage Range | 9.6 to 26.4 V DC |
Operating Voltage | 9.6 V DC max. |
Release Voltage | 1.0 V DC min. |
Input Current | DC 5 mA max. (with 12 V DC) DC 10 mA max. (with 24 V DC) |
Output OFF Collector Voltage | 30 V DC max. |
---|---|
Maximum Carry Current | 100 mA |
Output Format | NPN open collector (ON when error is detected) |
Minimum Load Current | 0.1 mA |
Model _x000D_ | Model G3PF-225B | Model G3PF-235B |
---|---|---|
Model G3PF-225B-CTB | Model G3PF-235B-CTB | |
Rated Load Voltage | 100 to 240 V AC 50/60 Hz | |
Operating Voltage Range | 75 to 264 V AC 50/60 Hz | |
Rated Carry Current * | 25 A (with 40°C) | 35 A (with 40°C) |
Minimum Load Current | 2 A | |
Inrush Current | 220 A (60 Hz, 1 cycle) | 430 A (60 Hz, 1 cycle) |
* Differs depending on ambient temperature. For details, see the catalog characteristics data "● Rated Load Current—Ambient Temperature."
Format | Model G3PF-225B | Model G3PF-235B | |
---|---|---|---|
Model G3PF-225B-CTB | Model G3PF-235B-CTB | ||
Operating Time | 1/2 of load power source cycle + 1 ms max. | ||
Release Time | 1/2 of load power source cycle + 1 ms max. | ||
Main Circuit | Output On Voltage Drop | 1.6 V (RMS) max. | |
Leakage Current | 10 mA max. (at 200 V AC) | ||
Alarm Output | Output On Voltage Drop | 1.5 V max. | |
Leakage Current | 1 μA max. | ||
Insulation Resistance | 100 MΩ min. (with 500 V ohmmeter) | ||
Dielectric Strength | 2,500 V AC 50/60 Hz for 1 min | ||
Vibration | 10 to 55 to 10 Hz, 0.35-mm single amplitude (0.7-mm double amplitude) | ||
Shock | 294 m/s2 | ||
Storage Temperature | -30 to +70°C (assuming no icing or condensation) | ||
Ambient Operating Temperature | -20 to +60°C (assuming no icing or condensation) | ||
Ambient Operating Humidity | 45 to 85% RH | ||
Weight | Approx. 400 g | Approx. 630 g |
Part Number |
---|
G3PF-235B-CTB DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Terminal shape | Safety standards | Dimension width (mm) | Dimension depth (mm) | Applicable output load (A)/(V) | Function |
---|---|---|---|---|---|---|---|---|---|---|
4,664,580 VND | 1 Piece(s) | 6 Day(s) or more | - | UL / TUV / CSA | 55 | 137 | 2 to 35A/AC100 to 240V | Warning Output 2 Point |
Loading...Tải…
Application | SSR | Dimension height(mm) | 100 | Insulation method | Phototriac Coupler |
---|---|---|---|---|---|
Zero cross function | Available | Operation Indicator Lamp | Available | Input rated voltage(V) | DC 12–24 |
Please check the type/dimensions/specifications of the part G3PF-235B-CTB DC24 in the CT Built-in Solid State Relay G3PF series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần G3PF-235B-CTB DC24 trong chuỗi CT Built-in Solid State Relay G3PF.
Part Number |
---|
G3PF-225B DC24 |
G3PF-225B-CTB DC24 |
G3PF-235B DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Terminal shape | Safety standards | Dimension width (mm) | Dimension depth (mm) | Applicable output load (A)/(V) | Function |
---|---|---|---|---|---|---|---|---|---|---|
2,380,000 VND | 1 Piece(s) | Same day | Screw Fastening | TUV / CSA | 45 | 110 | 2 to 25A/AC100 to 240V | Warning Output 1 Point | ||
4,165,278 VND | 1 Piece(s) | 6 Day(s) or more | - | UL / TUV / CSA | 45 | 117 | 2 to 25A/AC100 to 240V | Warning Output 2 Point | ||
3,738,271 VND | 1 Piece(s) | 6 Day(s) or more | Screw Fastening | TUV / CSA | 55 | 130 | 2 to 35A/AC100 to 240V | Warning Output 1 Point |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy