(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Communication unit for iQ-R series available.
AnyWireASLINK Master Unit RJ51AW12AL external appearance
AnyWireASLINK Master Unit RJ51AW12AL dimensional outline drawing
(Unit: mm)
Transmission Clock | 27.0 kHz | |
---|---|---|
Maximum Transmission Distance (Total Extension) | 200 m | |
Number of connectable units | Maximum 128 units (Varies depending on the current consumption of each slave unit.) | |
Transmission method | DC power supply superimposed total frame / cyclic method | |
Connection form | Bus type (multi-drop method, T-branching method, tree-branching method) | |
Transmission Protocol | Dedicated protocol (AnyWireASLINK) | |
Error Control Method | Checksum, double verification method | |
Number Of Connected I/O Points | Maximum 512 points (256 input points / 256 output points) | |
AnyWireASLINK Transmission Wire | ·UL compatible general purpose 2-wire cable (VCTF, VCT 1.25 mm^2, 0.75 mm^2, rated temperature 70°C or higher) ·UL compatible general-purpose cable (1.25 mm^2, 0.75 mm^2, rated temperature 70°C or higher) ·Dedicated ribbon cable (1.25 mm^2, 0.75 mm^2, rated temperature 90°C) | |
24 V DC Power Line | ·UL compatible general purpose 2-wire cable (VCTF, VCT 0.75 to 2.0 mm^2, rated temperature 70°C or higher) ·UL compatible general-purpose cable (0.75 to 2.0 mm^2, rated temperature 70°C or higher) ·Dedicated ribbon cable (1.25 mm^2, 0.75 mm^2, rated temperature 90°C) | |
External Power Supply | Voltage | 21.6 to 27.6 V DC (24 V DC, -10 to +15%) ripple voltage 0.5 V p-p or less Recommended voltage: 26.4 V (24 V DC, +10%) |
External Wiring Connection Method | 7‑Piece spring clamp terminal block, push-in type | |
Transmission Wire Supply Current | When using 1.25 mm^2 cable: MAX 2 A When using 0.75 mm^2 cable: MAX 1.2 A | |
Number Of Occupied Inputs/Outputs | 32 points (I/O assignment: Intelligent 32 points) | |
5 V DC Internal Current Consumption | 0.20 A | |
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) |
Width (W) | 27.8 mm | |
Depth (D) | 124 mm | |
Weight | 0.13 kg |
CC-Link System Master / Local Unit RJ61BT11 external appearance
CC-Link System Master / Local Unit RJ61BT11 dimensional outline drawing
(Unit: mm)
Transmission Speed | 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps (Selectable) | ||
---|---|---|---|
Station Type | Master station (Version 1 master station or version 2 master station) Local station (Version 1 local station or version 2 local station) | ||
Maximum Number Of Connected Devices | Master Station | 64 devices | |
Number Of Occupied Stations | Local Station | 1 to 4 stations | |
Maximum Link Points Per System | CC-Link Ver. 1 | Remote input/output (RX, RY): 2,048 points Remote register (RWw): 256 points Remote register (RWr): 256 points | |
CC-Link Ver. 2 | Remote input/output (RX, RY): 8,192 points Remote register (RWw): 2,048 points Remote register (RWr): 2,048 points | ||
Link Points Per Station | CC-Link Ver. 1 | Remote input/output (RX, RY): 32 points (30 points for local stations) Remote register (RWw): 4 points Remote register (RWr): 4 points | |
CC-Link Ver. 2 | Expanded cyclic setting: 1 times setting | Remote input/output (RX, RY): 32 points (30 points for local stations) Remote register (RWw): 4 points Remote register (RWr): 4 points | |
Expanded cyclic setting: 2 times setting | Remote input/output (RX, RY): 32 points (30 points for local stations) Remote register (RWw): 8 points Remote register (RWr): 8 points | ||
Expanded cyclic setting: 4 times setting | Remote input/output (RX, RY): 64 points (62 points for local stations) Remote register (RWw): 16 points Remote register (RWr): 16 points | ||
Expanded Cyclic Setting: × 8 Setting | Remote input/output (RX, RY): 128 points (126 points for local stations) Remote register (RWw): 32 points Remote register (RWr): 32 points | ||
Communication Method | Broadcast polling method | ||
Synchronization Method | Frame Synchronization Method | ||
Encryption Method | NRZI (Non Return to Zero Inverted) sign | ||
Transmission Path Type | Bus (RS-485) | ||
Transmission Format | HDLC Compliant | ||
Error Control Method | CRC (X16+X12+X5+1) | ||
Communication Cable | CC-Link dedicated cable compatible with Ver. 1.10 | ||
Maximum total cable length (Maximum transmission distance) | Ver. 1.10 | At 156 kbps | 1,200 m |
At 635 kbps | 900 m | ||
At 2.5 Mbps | 400 m | ||
At 5 Mbps | 160 m | ||
At 10 Mbps | 100 m | ||
Number Of Occupied Inputs/Outputs | 32 points (I/O assignment: Intelligent 32 points) | ||
5 V DC Internal Current Consumption | 0.34 A | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 27.8 mm | ||
Depth (D) | 131 mm | ||
Weight | 0.16 kg |
BACnet Unit RJ71BAC96 external appearance
BACnet Unit RJ71BAC96 dimensional outline drawing
(Unit: mm)
Transmission Specification | Data Transmission Speed | 100/10 Mbps |
---|---|---|
Communication Mode | Full Duplex / Half Duplex | |
Transmission Method | Base Band | |
Maximum Segment Length | 100 m (Length between the hub and the node) | |
IP Version | IPv6/IPv4 | |
BACnet Specification | Number Of Registrable Input/Output Objects | 4,000 instances |
Number Of Registrable CA Objects | 300 instances | |
Number Of Registrable SC Objects | 100 instances | |
Number Of Registrable TL Objects | 200 instances | |
Number Of Registrable NC Objects | 50 instances | |
Registrable Capacity In Read Access Block Area | Total 2,176 points | |
Registrable Capacity In Write Access Block Area | Total 2,176 points | |
Registrable Capacity In BACnet Monitor Access Block Area | 10,000 points in total | |
Registrable Capacity In COV Link Access Block Area | 10,000 points in total | |
Registrable Capacity In Event Link Access Block Area | 10,000 points in total | |
Number Of Occupied Inputs/Outputs | 32 points (I/O assignment: Intelligent 32 points) | |
5 V DC Internal Current Consumption | 0.61 A | |
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) |
Width (W) | 27.8 mm | |
Depth (D) | 110 mm | |
Weight | 0.19 kg |
Serial Communication Unit RJ71C24 external appearance
Serial Communication Unit RJ71C24 dimensional outline drawing
(Unit: mm)
Interface | CH. 1 | RS-232 Compliant (D-Sub 9P) | |
---|---|---|---|
CH. 2 | RS-422/485 Compliant (2‑piece Terminal Block) | ||
Communication Method | Circuit | Full-duplex communication / Half-duplex communication | |
MELSEC Communication Protocol Communication | Half-duplex communication | ||
Communication Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Nonprocedural Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Bi-Directional Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Synchronization Method | Asynchronous Method | ||
Transmission Speed | 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps | ||
Data Format | Start Bit | 1 | |
Data Bit | 7/8 | ||
Parity Bit | 1 (vertical parity) / None | ||
Stop Bit | 1/2 | ||
Access Cycle | MELSEC Communication Protocol Communication | One request is processed as part of the END processing of the CPU unit of the C24-installed station | |
Communication Protocol Communication | Both send and receive requests are executed based on a dedicated command. | ||
Nonprocedural Protocol Communication | Sending is performed for each transmission request Reception is always possible | ||
Bi-Directional Protocol Communication | Sending is performed for each transmission request Reception is always possible | ||
Error Detection | MELSEC Communication Protocol Communication | Parity Check | Applicable |
Checksum | Applicable | ||
Horizontal Parity | Not applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Communication Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Applicable | ||
16‑Bit CRC (MODBUS Specification) | Applicable | ||
Nonprocedural Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Bi-Directional Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Not applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Transmission Control | RS-232 | DTR/DSR Control | Applicable |
RS/CS Control | Applicable | ||
CD (DCD) Signal Control | Applicable | ||
DC1/DC3 (Xon/Xoff) Control | Applicable | ||
DC2 / DC4 Control | Applicable | ||
RS-422/485 | DTR/DSR Control | Not applicable | |
RS/CS Control | Not applicable | ||
CD (DCD) Signal Control | Not applicable | ||
DC1/DC3 (Xon/Xoff) Control | Applicable | ||
DC2 / DC4 Control | Applicable | ||
Line configuration of connections (Coupling device-side: CPU unit side) | RS-232 | 1: 1 | |
RS-422/485 | 1: 1, 1: n, n: 1, m: n (The total of n and m + n is up to 32) | ||
Line configuration of data communications (Coupling device-side: CPU unit side) | RS-232 | MELSEC Communication Protocol Communication | 1: 1 |
Communication Protocol Communication | 1: 1 | ||
Nonprocedural Protocol Communication | 1: 1 | ||
Bi-Directional Protocol Communication | 1: 1 | ||
RS-422/485 | MELSEC Communication Protocol Communication | 1: 1, 1: n, m: n (The total of n and m + n is up to 32) | |
Communication Protocol Communication | 1: 1, n: 1 (n is up to 32) | ||
Nonprocedural Protocol Communication | 1: 1, 1: n, n: 1 (n is up to 32) | ||
Bi-Directional Protocol Communication | 1: 1 | ||
Transmission distance | RS-232 | Maximum 15 m | |
RS-422/485 | Maximum 1,200 m (The total extension distance) | ||
Number Of Occupied Inputs/Outputs | 32 points (I/O assignment: Intelligent 32 points) | ||
5 V DC Internal Current Consumption | 0.31 A | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 27.8 mm | ||
Depth (D) | 110 mm | ||
Weight | 0.16 kg |
External appearance of serial communication unit RJ71C24-R2
Drawing of serial communication unit RJ71C24-R2
(Unit: mm)
Interface | CH. 1 | RS-232 Compliant (D-Sub 9P) | |
---|---|---|---|
CH. 2 | RS-232 Compliant (D-Sub 9P) | ||
Communication Method | Circuit | Full-duplex communication / Half-duplex communication | |
MELSEC Communication Protocol Communication | Half-duplex communication | ||
Communication Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Nonprocedural Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Bi-Directional Protocol Communication | Full-duplex communication / Half-duplex communication | ||
Synchronization Method | Asynchronous Method | ||
Transmission Speed | 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps | ||
Data Format | Start Bit | 1 | |
Data Bit | 7/8 | ||
Parity Bit | 1 (vertical parity) / None | ||
Stop Bit | 1/2 | ||
Access Cycle | MELSEC Communication Protocol Communication | One request is processed as part of the END processing of the CPU unit of the C24-installed station | |
Communication Protocol Communication | Both send and receive requests are executed based on a dedicated command. | ||
Nonprocedural Protocol Communication | Sending is performed for each transmission request Reception is always possible | ||
Bi-Directional Protocol Communication | Sending is performed for each transmission request Reception is always possible | ||
Error Detection | MELSEC Communication Protocol Communication | Parity Check | Applicable |
Checksum | Applicable | ||
Horizontal Parity | Not applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Communication Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Applicable | ||
16‑Bit CRC (MODBUS Specification) | Applicable | ||
Nonprocedural Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Bi-Directional Protocol Communication | Parity Check | Applicable | |
Checksum | Applicable | ||
Horizontal Parity | Not applicable | ||
16‑Bit CRC (MODBUS Specification) | Not applicable | ||
Transmission Control | RS-232 | DTR/DSR Control | Applicable |
RS/CS Control | Applicable | ||
CD (DCD) Signal Control | Applicable | ||
DC1/DC3 (Xon/Xoff) Control | Applicable | ||
DC2 / DC4 Control | Applicable | ||
Line configuration of connections (Coupling device-side: CPU unit side) | RS-232 | 1: 1 | |
Line configuration of data communications (Coupling device-side: CPU unit side) | RS-232 | MELSEC Communication Protocol Communication | 1: 1 |
Communication Protocol Communication | 1: 1 | ||
Nonprocedural Protocol Communication | 1: 1 | ||
Bi-Directional Protocol Communication | 1: 1 | ||
Transmission distance | RS-232 | Maximum 15 m | |
Number Of Occupied Inputs/Outputs | 32 points (I/O assignment: Intelligent 32 points) | ||
5 V DC Internal Current Consumption | 0.20 A | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 27.8 mm | ||
Depth (D) | 110 mm | ||
Weight | 0.14 kg |
Part Number |
---|
RJ71GF11-T2 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Communication Interface (Transmission Standard) | Number of Ports | Connection Terminal | Representative Standard | Type of unit | Transmission Speed | Specification details |
---|---|---|---|---|---|---|---|---|---|---|---|
7,677,500 VND | 1 Piece(s) | Quote | Ethernet | - | - | CE / UL / CUL | - | - | - |
Loading...Tải…
Please check the type/dimensions/specifications of the part RJ71GF11-T2 in the iQ-R Series Communication Unit series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần RJ71GF11-T2 trong chuỗi iQ-R Series Communication Unit.
Part Number |
---|
RJ61BT11 |
RJ71BAC96 |
RJ71C24 |
RJ71GN11-T2 |
RJ71GP21-SX |
RJ71GP21S-SX |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Communication Interface (Transmission Standard) | Number of Ports | Connection Terminal | Representative Standard | Type of unit | Transmission Speed | Specification details |
---|---|---|---|---|---|---|---|---|---|---|---|
3,496,250 VND | 1 Piece(s) | Quote | - | - | - | CE / UL / CUL | - | - | - | ||
66,855,000 VND | 1 Piece(s) | Quote | Other | - | - | CE | BACnet unit | - | - | ||
8,982,500 VND | 1 Piece(s) | Quote | Other | - | - | CE / UL / CUL | - | - | - | ||
8,802,500 VND | 1 Piece(s) | 98 Day(s) | Ethernet | 2 | Connector | CE / UL / CUL | CC-link IE TSN master/local unit | 1 Gbps / 100 Mbps | Standard specifications | ||
14,975,000 VND | 1 Piece(s) | Quote | Photonics | - | - | CE / UL / CUL | - | - | - | ||
1 VND | 1 Piece(s) | Quote | Photonics | 2 | Connector | CE / UL / CUL | CC-Link IE controller network unit | 1 Gbps | With external power supply function |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy