(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
[Features]
· HA-M type that supports center through coolant
· Characteristics and specifications conform to the HA-M type
· The flange through oil hole type (-OHF) is available upon order
· Unlike the spring collet, tap attachment and detachment can be performed in a single action
· Remeasurement of tool length after tap replacement is unnecessary
· The standard specification uses the TC-MO with feed pump pressures up to 2 MPa.
· Use the TC-MO-SB to handle feed pump pressures up to 5 MPa.
· Also Supports Mist Specifications
Part Number |
---|
BT50-HA1022-M-OHC |
BT50-HA2035-M-OHC |
BT50-HA412-M-OHC |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Spindle types | Holder Length L (mm) | C1 (mm) | Capacity Range | Mass (g) | L1 (mm) |
---|---|---|---|---|---|---|---|---|---|---|
11,172,294 VND | 1 Piece(s) | 7 Day(s) or more | BT50 | 165 | 50 | M8~M27 | 4100 | 100.0 | ||
15,325,438 VND | 1 Piece(s) | 7 Day(s) or more | BT50 | 210 | 72 | M18~M38 | 4920 | 125.0 | ||
9,978,797 VND | 1 Piece(s) | 7 Day(s) or more | BT50 | 135 | 35 | M3~M16 | 3730 | 91.5 |
Loading...Tải…
Product Category | Main Body | Applicable Manufacturing Machinery (main unit) | Machining Centers | Features | HA-M Type supporting center coolant-through. Specifications and characteristics accord with HA-M Type. Special flange-through oil hole type (-OHF) can be specially made to order. Unlike spring collet, tap attachment and detachment can be performed in single action. No tool length re-measurement after tap replacement necessary. Uses TC-MO Type with 2 MPa supply pump pressure as standard. Use of TC-MO-SB Type supports maximum supply pump pressure of 5 MPa. Can support mist specification. |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy