(!)Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site.Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
[Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
[Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more.
[Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
[Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement. Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Thermometers and hygrometers are measuring equipment used to measure temperature and humidity. Depending on the product, they can measure indoor temperature and humidity, surface temperature of objects, temperature of liquids, and the like. Thermo‑hygrometers, which can measure temperature and humidity at the same time, come in 2 types: analog and digital. Bimetal thermometers are products that have 2 strips of metal with different thermal expansion coefficients bonded to sense temperature by the expansion of the metals. The structure is simple, so maintenance is easy, and durability is high, so they are often used for industrial purposes. Radiation thermometers can measure without contacting the object to measure by radiating infrared rays. Remote thermometers measure temperature of distant objects, and analog and digital types can be selected. The temperature range that can be measured is determined by the measuring equipment, so the product must be selected according to its purpose.
Compact temperature module that can be assembled to devices.[Features]· Equipped with a highly durable thermistor sensor.· Its small size allows it to be embedded in a variety of devices.[Applications]· For temperature management of insulated boxes.· For incorporating in devices that require temperature display.
Product Type
Temperature Measuring Range(°C)
Temperature minimal display(°C)
Drip-proof and Waterproof function
Operating Temperature Range(°C)
Humidity Minimal Display(%RH)
Measured humidity range(%RH)
Heat Stroke Index display range(°C)
Primary Color
Color after discoloration
Thermometer (External Sensor Type)
-50~190
-
-
-
-
-
-
-
-
From:
632,138 VND
Days to Ship: Số ngày giao hàng:
4 Day(s) or more
4 Day(s) or more
You can add up to 6 items per a category to the compare list.
Compact temperature module that can be assembled to devices.[Features]· Equipped with a highly durable thermistor sensor.· Its small size allows it to be embedded in a variety of devices.[Applications]· For temperature management of insulated boxes.· For incorporating in devices that require temperature display.
Product Type
Temperature Measuring Range(°C)
Temperature minimal display(°C)
Drip-proof and Waterproof function
Operating Temperature Range(°C)
Humidity Minimal Display(%RH)
Measured humidity range(%RH)
Heat Stroke Index display range(°C)
Primary Color
Color after discoloration
Thermometer (External Sensor Type)
-50~190
-
-
-
-
-
-
-
-
From:
704,291 VND
Days to Ship: Số ngày giao hàng:
8 Day(s) or more
8 Day(s) or more
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
Product Type
Temperature Measuring Range(°C)
Temperature minimal display(°C)
Drip-proof and Waterproof function
Operating Temperature Range(°C)
Humidity Minimal Display(%RH)
Measured humidity range(%RH)
Heat Stroke Index display range(°C)
Primary Color
Color after discoloration
You can add up to 6 items per a category to the compare list.
You can add up to 6 items per a category to the compare list.
Question: How many types of thermometers and how to select them?
Answer: Thermometers for industrial use have 4 main types.
1. Liquid or gas-filled thermometers use a gas or liquid as the temperature-sensing element.
2. Bimetal or bi-metallic thermometers use a bimetal spring as the temperature-sensing element.
3. Electronic devices such as thermistors measure changes in electrical resistance and convert them to changes in temperature.
4. Infrared thermometers are non-contact devices that convert infrared (IR) energy to an electrical signal that can be displayed in units of temperature.
We should select the thermometer following factors, Measurement range, Application, and Operating Environment.
Question: Infrared thermometer, how to choose to use it properly?
Answer: Infrared thermometers are often used to measure the surface temperature of materials. Infrared thermometers measure temperature by the heat radiation emitted by an object. No need to contact with target object from a distance. Therefore, suitable for choosing to measure in the area hard-to-access area (such as overheating area or inside machinery)
Question: Which is the better digital or analog thermometer?
Answer: Analog and digital thermometers do the same job. However, they are very different. The different characteristics make both types suitable for different applications.
The advantages of analog types of thermometers are that they are cheap, easy to read, can be submerged in liquids, require very little maintenance, and are reliable. The disadvantages are that they break easily and there is a risk of mercury poisoning if the glass tube breaks.
On the hand, The advantages of digital thermometers are that they are easy to read, require very little maintenance and give an accurate reading. The disadvantage is that they get damaged easily if dropped and cannot use without the battery powering them.
Question: How Infrared Thermometers work
Answer: An Infrared thermometer measures both infrared radiation and the emissivity value of a surface. The infrared thermometer has a lens that focuses the infrared rays and tunnels them through the thermometer to a detector known as a thermopile. Then, the thermopile converts the incoming Infrared radiation into an electrical signal that is then displayed as digital units of temperature.
Question: How accurate of infrared thermometers?
Answer: Industrial infrared digital thermometers have an error factor that averages around ±1 to 1.5°C, which is more than satisfactory for most industrial applications.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy