(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 24/11/2024 to 6:00 (ICT) 25/11/2024. We apologize for the inconvenience.
  • [Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
    [Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more. 
  • [Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
    [Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.

OMRON Limit Switch(Plunger Shape Type:Multiple)

OMRON offers products Limit Switch specified by Plunger Shape Type Multiple from Automation Components product category. There are a total of 1 items. Search and select detailed specifications of parts for your machine with free CAD download. OMRON products are available to order through MISUMI online 24/7. Free shipping, no minimum order.
CAD
Days to Ship
  • All
  • Same day
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • Others

1 itemsMặt hàng

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]

    Multi-Pull Limit Switch [VB]

    OMRON

    VB type appeared with new form. Improvement in strength and sealing property of head with integrated head box. Drastic improvement in mechanical durability.[Features]· Possible to use in various types of machine tools and sequence controlling such as transfer/machine.· Possible to remove oil/water though entered into the plunger as oil filter is provided.· Approved by EN/IEC (only with earth terminal), and approved by CCC.· The product with earth terminal supports CE marking.

    CAD :
    3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type Standard Standard / Oil Resistant / Water Resistant Multiple 2 / 3 / 4 / 6 - - - Single Pole Double Throw - - AC100/125V / AC240/250V 10
    From: 2,400,000 VND
    Days to Ship: Số ngày giao hàng: 4 Day(s) or more
    day to ship 4 Day(s) or more
BrandNhãn hiệu
Product SeriesDòng sản phẩm
CADCAD
From
Days to ShipSố ngày giao hàng
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

    You can add up to 6 items per a category to the compare list.

    Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      Multi-Pull Limit Switch [VB]
      BrandNhãn hiệu

      OMRON

      Product SeriesDòng sản phẩm

      Multi-Pull Limit Switch [VB]

      CADCAD
      • 3D
      From

      2,400,000 VND-

      Days to ShipSố ngày giao hàng 4 Day(s) or more
      Detector ShapePlunger Type
      Main Body SizeStandard
      EnvironmentStandard / Oil Resistant / Water Resistant
      Plunger Shape TypeMultiple
      Number of Plunger Rows2 / 3 / 4 / 6
      Roller Lever Shape Type-
      Lever Shape Type-
      Rod Shape Type-
      Contact TypeSingle Pole Double Throw
      Contact Point Type-
      Contact Material-
      Rated Operating Voltage(V)AC100/125V / AC240/250V
      Rated Conductance Current(A)10

      Loading...Tải…

      1. 1

      Related Categories to Limit SwitchDanh mục liên quan đến Limit Switch

      FAQ Limit Switch

      Question: Can the Limit switch be used for doors?
      Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."

      There are two main types of safety limit switches suitable for door safety:

      Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.

      Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
      Question: What is the purpose of a Limit switch with a long lever?
      Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.

      For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.

      In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
      Question: How do I connect or install a limit switch?
      Answer: Step by step to install the limit switch
      1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
      2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
      3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
      4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
      5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
      6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
      7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
      8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
      9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
      10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.