Current Sensors(Mounting Method:DIN Rail Mounting)
Current Sensors products in the Automation Components category. Specified by Mounting Method DIN Rail Mounting. There are around 6 items of Current Sensors products available and the specifications can easily be compared. Search and select detailed specifications of parts for your machine with free CAD download. Current Sensors offers a wide selection, on time free shipping no minimum order with 24/7 support.

Brand |
|
CAD |
|
Days to Ship |
- All
- Same day
- 6 Day(s) or Less
- 10 Day(s) or Less
- 11 Day(s) or Less
- 12 Day(s) or Less
- Others
|
Mounting Method: DIN Rail Mounting
X
-
From:
2,765,877 VND
|
Days to Ship:
Số ngày giao hàng:
6 Day(s) or more
|

6 Day(s) or more
-
Over Current Alarm External Sensor and Large Current-capable Over Current Alarm 5 A to 200 A Program Method
URD
[Features]· Over-current warning machine to detect abnormalities of various electronic devices, motor overload / partial short circuit of heater.· In the structure that does not require externally controlled power supply, it is compatible to large current type with an external sensor attached.· Power supply is, 100V/200V can be shared with taps.· Operating point is, 5A to 200A accurate overload can be detected using programming method.· The dead zone timer prevents malfunction till current settling for motor startup current, and for starting mode such as magnetizing inrush current of transformer.· Operation display LED including operation point setting is easy.· Alarm output is non-voltage 1 transfer contact.
5~200
|
Alternating Current (AC)
|
-
|
DIN Rail Mounting
|
From:
3,295,839 VND
|
Days to Ship:
Số ngày giao hàng:
11 Day(s) or more
|

11 Day(s) or more
-
From:
2,765,877 VND
|
Days to Ship:
Số ngày giao hàng:
6 Day(s) or more
|

6 Day(s) or more
-
From:
6,405,976 VND
|
Days to Ship:
Số ngày giao hàng:
10 Day(s) or more
|

10 Day(s) or more
-
Disconnection alarm external sensor/small current supported disconnection alarm, 0.5 A - 20 A program system
URD
[Features]· Method to distinguish it as disconnection in case of insufficient voltage and insufficient current (does not supporting cycle control).· With no externally controlled power supply, it supports external sensor having small current.· Power supply is, 100V/200V can be shared with taps.· Operating point is, 0.5A to 20A can be set by programming method.· Operation display LED including operation point setting is easy.· Alarm output is non-voltage 1 transfer contact.· Standard item with built-in CT (CRY-CP) compatible with CT external type.
0.5~20
|
Alternating Current (AC)
|
-
|
DIN Rail Mounting
|
From:
3,543,313 VND
|
Days to Ship:
Số ngày giao hàng:
12 Day(s) or more
|

12 Day(s) or more
-
From:
3,295,839 VND
|
Days to Ship:
Số ngày giao hàng:
11 Day(s) or more
|

11 Day(s) or more
|
---|
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
---|
From |
---|
Days to ShipSố ngày giao hàng |
---|
Applicable Current(A)
|
---|
Input Current
|
---|
Through Hole(φ)
|
---|
Mounting Method
|
---|
| | | | | | |
---|
BrandNhãn hiệu | URD | URD | URD | URD | URD | URD |
---|
Product SeriesDòng sản phẩm | Overcurrent AlarmBuilt-in Senor and Power Supply Direct Connected Type Overcurrent Alarm0.2 A-20 A Program Method | Over Current Alarm External Sensor and Large Current-capable Over Current Alarm 5 A to 200 A Program Method | Disconnection alarm built-in sensor and current direct connection type disconnection alarm 0.2 A to 20 A program method | Electric passage/leakage detecting module and Electric leakage detecting module (contact output type) | Disconnection alarm external sensor/small current supported disconnection alarm, 0.5 A - 20 A program system | Disconnection alarm external sensor and large current corresponding type disconnection alarm 5 A to 200 A program method |
---|
From |
2,765,877 VND
|
3,295,839 VND
|
2,765,877 VND
|
6,405,976 VND
|
3,543,313 VND
|
3,295,839 VND
|
---|
Days to ShipSố ngày giao hàng |
6 Day(s) or more
|
11 Day(s) or more
|
6 Day(s) or more
|
10 Day(s) or more
|
12 Day(s) or more
|
11 Day(s) or more
|
---|
Applicable Current(A) | 0.2~20 | 5~200 | 0.2~20 | 0.0025~0.15 | 0.5~20 | 5~200 |
---|
Input Current | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) |
---|
Through Hole(φ) | - | - | - | - | - | - |
---|
Mounting Method | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting |
---|
|
---|
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
---|
Loading...Tải…
Specification/DimensionsĐặc điểm kỹ thuật / Kích thướcĐặc điểm kỹ thuật / Kích thước
-
Applicable Current(A)
- -800~800
- -500~500
- -250~250
- -200~200
- -150~150
- -100~100
- -50~50
- -25~25
- -20~20
- -15~15
- -10~10
- -5~5
- -3~3
- -0.1~0.1
- 0~25
- 0~500
- 0.0005~100
- 0.001~15
- 0.001~20
- 0.001~80
- 0.001~100
- 0.001~200
- 0.001~280
- 0.0025~0.15
- 0.01~15
- 0.01~60
- 0.01~80
- 0.01~120
- 0.01~200
- 0.02~200
- 0.1~40
- 0.1~80
- 0.1~120
- 0.1~150
- 0.1~180
- 0.1~280
- 0.1~300
- 0.1~320
- 0.1~500
- 0.1~800
- 0.2~20
- 0.5~20
- 1
- 1~10
- 1~20
- 2~50
- 5~200
- 10~100
-
Input Current
-
Alternating Current (AC)
-
DC
-
Through Hole(φ)
- 5.8
- 6
- 8.5X17.5
- 10
- 12
- 16
- 18
- 20
- 24
- 36
-
Mounting Method
-
Not Fixed
-
Panel Mounting
-
Mounting of Substrate
-
DIN Rail Mounting
Application example related to this categoryVí dụ ứng dụng liên quan đến danh mục này
Related Categories to Current SensorsDanh mục liên quan đến Current Sensors
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy