(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Application | Switching Type | Voltage | Mounting Orientation | Pipe Port Type | Plumbing Thread Nominal | Plumbing | Lead wire electrical entry | Indicator light / Surge voltage suppressor | Bracket | Piping specifications | Type of manual operation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Grommet (lead wire length: 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Grommet (lead wire length: 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor (non-polar type) | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor (non-polar type) | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | 31 Day(s) | - | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | M-type plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | M plug connector (without connector) | - | No bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Direct Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC12V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC12V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC12V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For manifold | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC12V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC5V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Grommet (lead wire length: 300 mm) | Without indicator light / surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Grommet (lead wire length: 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Grommet (Lead length 600 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor (non-polar type) | No bracket | - | Non-lock push type | ||
1,267,000 VND | 1 Piece(s) | 32 Day(s) | - | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M plug connector (without connector) | Without indicator light / surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M plug connector (without connector) | With indicator light and surge voltage suppressor (non-polar type) | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | M plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | With surge voltage suppressor | No bracket | - | Non-lock push type | ||
1,267,000 VND | 1 Piece(s) | 32 Day(s) | - | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | Grommet (lead wire length: 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | Grommet (Lead length 600 mm) | With surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | Grommet (Lead length 600 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | - | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For manifold | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | 31 Day(s) | - | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC12V | Manifold Base | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | For manifold | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC12V | Direct | M | M3 | Direct Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | With Bracket | For body porting of P, R and A ports | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Sub-Base Plumbing | Grommet (lead wire length: 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Sub-Base Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking driver operation type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Sub-Base Plumbing | L plug connector (without connector) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor (non-polar type) | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Single Use | 2-Position Normally Open | DC24V | Direct | M | M3 | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | With indicator light and surge voltage suppressor | No bracket | - | Push-turn locking hand-operated type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC24V | Manifold Base | - | - | Sub-Base Plumbing | M-type plug connector (With lead length 300 mm) | With surge voltage suppressor | No bracket | - | Non-lock push type | ||
- | 1 Piece(s) | Quote | 10 | Unit for Manifold Mounting | 2-Position Normally Open | DC12V | Manifold Base | - | - | Sub-Base Plumbing | L-shaped plug connector (With lead length 300 mm) | Without indicator light / surge voltage suppressor | No bracket | - | Non-lock push type |
Loading...Tải…
Number of Ports | 3-Port Valve | Number of Solenoids | Single | Specifications | Lubrication Free / Clean Room |
---|---|---|---|---|---|
Status at Power Off | Self-Recovery (Spring Return) | Type | Solenoid Valves | Driving Type | Pilot Type Spool |
Pressure Rating(MPa) | 0 to 0.7 | Seal Type | Soft Seal | CV Value | 0.012 |
Pilot Air Supply | Internal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy