(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Brand |
|
---|---|
Filter By |
|
CAD |
|
Days to Ship |
|
53 itemsMặt hàng
You can add up to 6 items per a category to the compare list.
ATEX Directive, Rotary Actuator, Vane Type 56-CRB1 Series, ATEX Category 3
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator Both Sides Shaft Outputs | Round Shape | 90° / 100° / 180° | 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 | Single Vane / Double Vane | Standard | Standard | - | N/A | 0.01 to Less Than 0.1 / 0.1 to Less Than 1 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
ATEX Directive, Rotary Actuator, Vane Type 55-CRB2 Series, ATEX Category 2
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Round Shape | 90° / 180° / 270° | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | Single Vane / Double Vane | Standard | Standard | - | N/A | Less than 0.005 / 0.01 to Less Than 0.1 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
ATEX Directive, Rotary Actuator, Vane Type 56-CRB2 Series, ATEX Category 3
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator Both Sides Shaft Outputs | Round Shape | 90° / 180° / 270° | 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 | Single Vane / Double Vane | Standard | Standard | - | N/A | Less than 0.005 / 0.01 to Less Than 0.1 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
ATEX Directive, Rotary Actuator, Free Mount Type, 55-CRBU2 Series
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator Both Sides Shaft Outputs | Round Shape Block Mount | 90° | 3 ~ Less than 6 | Single Vane | Standard | Standard | - | N/A | 0.01 to Less Than 0.1 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
ATEX Directive, Rotary Actuator, Free Mount Type, 56-CRBU2 Series
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator Both Sides Shaft Outputs | Round Shape Block Mount | 90° | Less than 1 / 1 to Less Than 3 | Single Vane | Standard | Standard | - | N/A | Less than 0.005 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
ATEX Directive, Low Profile Rotary Actuator, Rack and Pinion Type, 55-CRQ2 Series
SMC
[What is the ATEX directive?]Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.■CE mark and ATEXThe ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.■Purpose of ATEX DirectiveThe main purposes of ATEX are:・ Prevention of static charge・ Ignition prevention of sparks caused by friction, impact, and wear・ Ignition prevention due to temperature rise due to the same as above・ The responsibility lies with the manufacturer・ Certification by zone/category■Zone / category divisionIn ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).・ Zone 0: Category 1Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year・ Zone 1: Category 2Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year・ Zone 2: Category 3Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Block Shape | 90° / 180° | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 | Double Rack | Standard | Standard | - | N/A | 0.01 to Less Than 0.1 / 0.1 to Less Than 1 |
Days to Ship: Số ngày giao hàng: Quote |
You can add up to 6 items per a category to the compare list.
CKD
A vane-type rotary actuator that is compact, lightweight, and has high torque with little air leakage.
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
Rotary Actuator One Side Shaft Output | Block Shape | 90° | 1 to Less Than 3 | Single Vane | Standard | Standard | - | N/A | - |
From: 3,776,822 VND |
---|
Days to Ship: Số ngày giao hàng: 16 Day(s) or more |
You can add up to 6 items per a category to the compare list.
FESTO
[Specifications]The compact and robust quarter turn actuator DAPS with lever-rocker kinematics is specially designed to meet the requirements of the process industry.• High breakaway torques• Approved in accordance with Directive 2014/34/EU (ATEX)• Flange hole pattern to ISO 5211• Mounting hole pattern to VDI/VDE 3845• Available with handwheel as a manual emergency override• Corrosion-resistant variant made from stainless steel
Type | Main Body Shape | Oscillation Angle A | Torque(N・m) | Operation Method | Environment, Applications | Rigidity, Accuracy | Tube Nominal Dia. | Valves | Allowable Kinetic Energy(J) |
---|---|---|---|---|---|---|---|---|---|
- | - | - | - | - | - | - | - | - | - |
From: 9,848,456 VND |
---|
Days to Ship: Số ngày giao hàng: 15 Day(s) |
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
CADCAD |
From |
Days to ShipSố ngày giao hàng |
Type |
Main Body Shape |
Oscillation Angle A |
Torque(N・m) |
Operation Method |
Environment, Applications |
Rigidity, Accuracy |
Tube Nominal Dia. |
Valves |
Allowable Kinetic Energy(J) |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
BrandNhãn hiệu | SMC | SMC | SMC | SMC | SMC | SMC | CKD | FESTO |
Product SeriesDòng sản phẩm | ATEX Directive, Rotary Actuator, Vane Type 56-CRB1 Series, ATEX Category 3 | ATEX Directive, Rotary Actuator, Vane Type 55-CRB2 Series, ATEX Category 2 | ATEX Directive, Rotary Actuator, Vane Type 56-CRB2 Series, ATEX Category 3 | ATEX Directive, Rotary Actuator, Free Mount Type, 55-CRBU2 Series | ATEX Directive, Rotary Actuator, Free Mount Type, 56-CRBU2 Series | ATEX Directive, Low Profile Rotary Actuator, Rack and Pinion Type, 55-CRQ2 Series | ||
CADCAD |
| |||||||
From | 3,776,822 VND | 9,848,456 VND | ||||||
Days to ShipSố ngày giao hàng | Quote | Quote | Quote | Quote | Quote | Quote | 16 Day(s) or more | 15 Day(s) |
Type | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output | - |
Main Body Shape | Round Shape | Round Shape | Round Shape | Round Shape Block Mount | Round Shape Block Mount | Block Shape | Block Shape | - |
Oscillation Angle A | 90° / 100° / 180° | 90° / 180° / 270° | 90° / 180° / 270° | 90° | 90° | 90° / 180° | 90° | - |
Torque(N・m) | 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 | 3 ~ Less than 6 | Less than 1 / 1 to Less Than 3 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 | 1 to Less Than 3 | - |
Operation Method | Single Vane / Double Vane | Single Vane / Double Vane | Single Vane / Double Vane | Single Vane | Single Vane | Double Rack | Single Vane | - |
Environment, Applications | Standard | Standard | Standard | Standard | Standard | Standard | Standard | - |
Rigidity, Accuracy | Standard | Standard | Standard | Standard | Standard | Standard | Standard | - |
Tube Nominal Dia. | - | - | - | - | - | - | - | - |
Valves | N/A | N/A | N/A | N/A | N/A | N/A | N/A | - |
Allowable Kinetic Energy(J) | 0.01 to Less Than 0.1 / 0.1 to Less Than 1 | Less than 0.005 / 0.01 to Less Than 0.1 | Less than 0.005 / 0.01 to Less Than 0.1 | 0.01 to Less Than 0.1 | Less than 0.005 | 0.01 to Less Than 0.1 / 0.1 to Less Than 1 | - | - |
Loading...Tải…
There might be logical torque values. Please refer to technical data of each manufacturer for details
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy